30" Over-the-Range Microwave Specifications

Product Weight – 70 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.71 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.)

Amps @ 120 Volts = 14.3 Amps

Always consult local and national electric codes.

Grounded outlet should be located in cabinet above, with hole in base

to route power cord. Carefully follow top template instructions for power

cord clearance when installing beneath smooth, flat cabinets.

Microwave’s ventilation system is preset to recirculate air inside with

no ducting system required. Exhausting air outside is optional, using

either vertical or horizontal ducting system. (Refer to Ducted Option

Specifications for outside ventilation.)

For safe and proper installation, microwave MUST be mounted to BOTH

a top cabinet AND a wall, and connected to at least one wall stud. Can

NOT be installed in island or peninsula cabinet arrangements.

Cabinet bottom MUST be level to insure proper installation.

Cabinet MUST be capable of supporting a total load of 135 lbs.

Filler blocks recommended for installation when cabinet front hangs

below recessed bottom shelf.

Minimum distance of 30" required from cooking surface to bottom edge

of top cabinet.

Minimum distance of 66" required from floor to top of microwave.

Opening between cabinets MUST be 30" wide and free of obstructions.

For openings up to 36" wide, order optional 36" Filler Kit to fill in gap

between unit and cabinets.

Allow 26" minimum clearance for 90° door swing.

Over-the-Range Microwave

EI30BM60MS

Electrolux Major Appliances, N.A.

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-877-4electrolux (1-877-435-3287)

electroluxappliances.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxappliances.ca

EI30BM60M 09/13

© 2013 Electrolux Home Products, Inc.

Ducted Option Specifications

For outside ventilation.

Exhaust duct adapter will be needed for outside ventilation, to mate

with standard 3-1/4" x 10" rectangular duct. If round duct required,

rectangular-to-round transition adapter will be needed with no more

than 6" diameter.

For most efficient airflow exhaust, use a straight run or as few elbows

as possible with a maximum duct length of 3-1/4" x 10" rectangular or

6" diameter round duct, not to exceed 120 equivalent feet.

For horizontal installation, be sure to allow enough space between wall

studs to accommodate exhaust.

Refer to installation instructions on web for detailed duct preparation and

converting exhaust vent blower system for exterior exhaust ventilation.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories