Electrical system requirements

Water supply requirements

Grounding requirements

Drain system requirements

CIRCUIT - Individual, properly polarized and

grounded 15 amp. branch circuit fused with 15
amp. time delay fuse or circuit breaker.

POWER SUPPLY - 2 wire, with ground, 120 volt

single phase, 60 Hz, Alternating Current.

OUTLET RECEPTACLE - Properly grounded

3-prong receptacle to be located so the power
supply cord is accessible when the washer is in
an installed position.

Grounding type

Grounding type
wa

wall receptacl

ll receptacle

Po

Power cord with

wer cord with

3-prong

3-prong gr

grounded plug

ounded plug

Do not,

Do not, under

under

an

any cir

y circumstances,

cumstances,

cut,

cut, remo

remove

ve,

or b

or bypass th

ypass the

gr

grounding pr

ounding prong.

ong.

Installation Requirements

NOTE

Because of potentially inconsistent voltage
capabilities, the use of this washer with power
created by gas powered generators, solar
powered generators, wind powered generators
or any other generator other than the local utility
company is not recommended.

NOTE

Drain hose attached to the washer can reach a 79
in. (201 cm) high standpipe. For higher standpipe,
use hose P/N 137098000, available from an
authorized parts distributor.

NOTE

GFI (Ground Fault Interrupter) receptacle is not
required.

WARNING

ELECTRICAL SHOCK HAZARD

Improper connection of the equipment grounding
conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt
as to whether the appliance is properly grounded.

1. The washer MUST be grounded. In the event

of malfunction or breakdown, grounding will
reduce the risk of electrical shock by a path of
least resistance for electrical current.

2. Since your washer is equipped with a power

supply cord having an equipment-grounding
conductor and a grounding plug, the plug
MUST be plugged into an appropriate, copper
wired receptacle that is properly installed and
grounded in accordance with all local codes and
ordinances or in the absence of local codes,
with the National Electrical Codes, ANSI/NFPA
70 (latest edition). If in doubt, call a licensed
electrician. DO NOT cut off or alter the grounding
prong on the power supply cord. In situations
where a two-slot receptacle is present, it is
the owner’s responsibility to have a licensed
electrician replace it with a properly grounded
three prong grounding type receptacle.

Hot and cold water faucets MUST be installed
within hose length of your washer’s water inlet. The
faucets MUST be 3/4 inch (1.9 cm) with thread-
ing for laundry hose connection. Water pressure
MUST be between 30 and 120 psi. Pressure differ-
ence between hot and cold cannot be more than
10 psi. Your water department can advise you of
your water pressure.

1. Drain capable of eliminating 17 gals (64.3 L) per

minute.

2. A standpipe diameter of 1-1/4 in. (3.18 cm)

minimum.

3. The standpipe height above the fl oor should be:

Minimum height: 24 in. (61 cm)
Maximum height: 96 in. (244 cm)

96”

(244cm)

max.

24”

(61cm)

min.