Cooktop / Downdraft Vent
Countertop Preparation Specifications

For detailed Cooktop installation, refer to model-specific product page
and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.

Position cooktop / vent cutout so all required minimum clearances are met.

Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth may NOT be
adequate for some cooktop / vent installations, especially with backsplash.

Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)

Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.

Downdraft Vent Specifications

For detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)

Amps @ 120 Volts = 8.0 Amps

Vent unit outside of building only.

Vent must be installed in vertical orientation only.

1,600 CFM remote exhaust blower (PN # 5304444802) included with
vent – shipped in separate box.

Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.

When multiple elbows are necessary, ensure a minimum of 24" of
straight duct between any two elbows.

Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.

For most efficient airflow exhaust, use a straight run or as few elbows
as possible.

Cold weather installations should have additional backdraft damper
installed.

Installing a Downdraft Vent in combination with any gas cooking
surface will affect optimum burner efficiency.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxappliances.com for detailed instructions.

Cooktop/Downdraft Vent
Countertop Preparation

High standards of quality at Electrolux Home Products, Inc. mean

we are constantly working to improve our products. We reserve the right

to change specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-877-4electrolux (1-877-435-3287)

electroluxappliances.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxappliances.ca

DIC_DDV_PREP EL 10/10

© 2010 Electrolux Home Products, Inc.

Printed in the U.S.A.

Countertop Preparation for 30" & 36" Cooktop / Downdraft Vent Installation

For detailed cooktop and downdraft vent installation specifications, refer to model-specific product page and installation guide on web

2

9

/

16

"

1

/

4

" min.

flat ledge

Backsplash

3

/

4

" max.

* Overall flat ledge behind

backside of cabinet front

** Minimum flat surface

required to fit top surface
of cooktop and downdraft
vent cap

A

Vertical noncombustible surface - rear wall

25"

B

Top

23

1

/

4

"

min.

Flush with

back side of

cabinet front

D*

E**

C

Stiffener

Back side of

cabinet front

Vent unit

2

1

/

8

"

Countertop
raised lip

Countertop
backsplash

Downdraft
chimney top

Cooktop

25"

(standard countertop)*

23

1

/

4

" min.

2

13

/

16

"

3"

Vertical noncombustible surface - rear wall

Studwall

3

/

4

" max. backsplash thickness

1

/

4

" min. flat ledge

1

15

/

16

"

9

/

32

"

2

13

/

16

"

Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements. Due to varying cooktop depths, tight fit
is possible between cooktop and vent.

Countertop Preparation Note:
Be aware of areas of potential interference called out in
illustration. Countertop with raised lip and/or backsplash may
not allow enough flat area for proper installation, 2-13/16"
of flat countertop required behind cooktop. No gap required
between back of cooktop and front of downdraft trim piece.

*Standard 25" countertop depth may NOT be adequate for

some cooktop / vent installations, especially with backsplash.

E30DD75ESS / 30" Cooktop Cutout Dimensions

30" Cooktops

A

B

C

D

E

EW30IC60I

30"

27

3

/

4

"

20

1

/

2

"

23

5

/

16

" 24

5

/

16

"

EW30CC55G

30"

27

3

/

4

"

20

1

/

2

"

23

5

/

16

" 24

5

/

16

"

EW30EC55G

30"

27

3

/

4

"

20

5

/

8

"

23

7

/

16

" 24

7

/

16

"

EW30GC55G

28

1

/

2

"

27

3

/

4

"

19

3

/

4

"

22

9

/

16

" 23

9

/

16

"

EW30GC60I

28

1

/

2

"

27

3

/

4

"

19

3

/

4

"

22

9

/

16

" 23

9

/

16

"

E36DD75ESS / 36" Cooktop Cutout Dimensions

36" Cooktops

A

B

C

D

E

EW36IC60I

36

1

/

4

"

33

3

/

4

"

20

1

/

2

"

23

5

/

16

" 24

5

/

16

"

EW36CC55G

36

1

/

4

"

33

3

/

4

"

20

1

/

2

"

23

5

/

16

" 24

5

/

16

"

EW36EC55G

36"

33

3

/

4

"

20

5

/

8

"

23

7

/

16

" 24

7

/

16

"

EW36GC55G

34

1

/

4

"

33

3

/

4

"

19

3

/

4

"

22

9

/

16

" 23

9

/

16

"

This manual is related to the following products: