beautypg.com

ADIC DAS V3.10E User Manual

Page 22

background image

22

Release Notes

603108

Rev

A

ET85105

"Multiple problem with scr_insert dasadmin
command". There is a bug in the DAS insert
command handler, which leads to a buffer
overflow. In addition, the aci_insert() function has
a limitation on buffer size (approx. 1 Kbyte).
Operating a large EIF (mailbox) with optical (two-
sided) volser this function could encounter
problems. Now aci_insert2() function will be
introduced (in ACI 3.10E) to fix this issue.

ET84186

"Improper DAS reaction on mount used drive".
There is an old check for "mount while cleaning"
condition, which is wrong.

DualDAS issues. There are several issues related
with Dual DAS system. There are errors in
transferring control information between active
and passive DASes

ET60326

"Scratch volumes are possible in more then one
pool".

"scr_set” doesn't create pool information in
database. Will be added.

ET60325

"select of scratch volumes doesn't check
information in database".
Will be fixed in DAS 3.10E.

Table 5

Problems solved with DAS 3.10E

Ticket

Number

Description