UEi Test Instruments ECT690 User Manual
Ect690, Limited warranty
ECT690
®
INST RUC T ION MA NUA L
1 - 8 0 0 - 5 47 - 5740 • Fax: (503) 643-6322
www. u e i t e s t . com • email: [email protected] m
Introduction
Use the ECT690 to perform quick checks of AC Volts,
DC Volts, and Continuity. LED’s indicate Voltage level
and DC polarity, tone provides audible indication of
Continuity.
Features include
• AC Volts 12 to 690
• DC Volts 6 to 220
• Continuity
• One year limited warranty
Safety Notes
• Never use the tester if it or its test leads
appear damaged.
• Never apply more than 1000V DC or 1000V AC
rms. between any terminal and earth ground.
•
I n d i cates dangerous voltage present at the
terminals if the LED turns on.
• When using the probes, do not touch the metal
probe tips.
• Disconnect the live test lead before disconnecting
the common test lead.
• Before each use, verify the tester’s operation by
measuring a known voltage.
Operating Instructions
Automatic Operation
The tester automatically turns on when you place the
probes across a complete circuit. The tester selects con-
tinuity or DC or AC voltage mode based on the resist-
ance or voltage between the probes. The tester auto-
matically turns off when you remove the probes from
the complete circuit.
Measuring Voltage
Connect test leads across the source or load under
measurement. The LEDs turn on at between 70% and
100% of their rated voltages.
ECT690
Electrical Te s t e r
Limited Warranty
The ECT690 is warranted to be free from defects in materials and
workmanship for a period of one year from the date of purchase. If
within the warra n ty period your instrument should become
i n o p e rative from such defects, the unit will be repaired or replaced
at UEi’s option. This warra n ty covers normal use and does not cover
damage which occurs in shipment or failure which results from
a l t e ration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from
failed batteries are not covered by warra n ty.
Any implied warranties, including but not limited to implied
warranties of merchantability and fitness for a particular purpose,
are limited to the express warranty. UEi shall not be liable for loss
of use of the instrument or other incidental or consequential
damages, expenses, or economic loss, or for any claim or claims
for such damage, expenses or economic loss. A purchase receipt or
other proof of original purchase date will be required before warra n ty
repairs will be rendered. Instruments out of warra n ty will be repaired
(when repairable) for a service charge. Return the unit postage paid
and insured to:
1-800-547-5740 • FAX: (503) 643-6322
www.ueitest.com • Email: [email protected]
This warranty gives you specific legal rights. You may also
have other rights which vary from state to state.
Copyright © 2008 UEi
ECT690-MAN 2/08
DC Voltage
1000V DC maximum
+VDC
-VDC
VDC
+
-
6
12
24
12V DC