What results are generally acceptable – UEi Test Instruments C20KIT User Manual
Page 8

6
a
tmoSpheriC
g
aS
f
ired
b
urNerS
• CO2 ................................................................................... 7.0 to 8.0% CO2
• Stack Temperature ......................................................... 325 to 500°F
• Draft (Water Column Inches) .......................................... -.02 to -.04wc”
• Carbon Monoxide (parts per million) ............................ <100ppm
g
aS
f
ired
p
ower
b
urNerS
• CO2 ................................................................................... 6.0 to 7.0% CO2
• Stack Temperature ......................................................... 275 to 500°F
• Stack Draft (Water Column Inches) ............................... -.02 to -.04wc”
• Overfire Draft (Water Column Inches) .......................... -.02wc”
• Carbon Monoxide (parts per million) ............................ <100ppm
o
il
f
ired
b
urNerS
(#2 o
il
f
uel
)
• CO2 ................................................................................... 6.6 to 8.0% CO2
• Stack Temperature ......................................................... 325 to 600°F
• Stack Draft (Water Column Inches) ............................... -.04 to -.06wc”
• Overfire Draft (Water Column Inches) .......................... -.02wc”
• Carbon Monoxide (parts per million) ............................ <100ppm
• Smoke .............................................................................. 0
(or manufacturer’s recommendation)
p
oSitive
o
verfire
g
aS
& o
il
• CO2 ................................................................................... 5.8 to 10.3% CO2
• Stack Draft (Water Column Inches) ............................... -.02 to -.04wc”
• Overfire Draft (Water Column Inches) .......................... +0.4 to +0.6wc”
• Carbon Monoxide (parts per million) ............................ <100ppm
NOTE: Follow manufacture guidelines for the specific equipment being serviced.
- Temperature and draft targets are included for reference only.
The C20 does not measure these parameters
WHAT RESULTS ARE GENERALLY ACCEPTABLE