Maintenance, Using the prosafe one monitor continued – ProMariner ProSafe One User Manual
Page 6
4
7
I n s t a l l a t i o n G u i d e l i n e s
M a i n t e n a n c e & A c c e s s o r i e s
Typical Hookup for Single 30 Amp/120 Volt Inlet
Typical Hookup for Dual 30 Amp/120 Volt Inlets
Optional Accessories
Part No. ProSafe One System Components
22079
ProSafe One main unit - single shore cord
22080
ProSafe One main unit - dual shore cord
22075
ProSafe One remote display
22110
1 meter isolator sense cable
22111
4 meter isolator sense cable
22112
7 meter isolator sense cable
22113
10 meter isolator sense cable
22115
3 meter remote extension cable
22033
30 amp ProSafe galvanic isolator
22066
60 amp ProSafe galvanic isolator
Call your Professional Mariner Dealer or representative for the monitor best suited for
your application.
We are committed to customer satisfaction and value your business. If at any time during
the warranty period you experience a problem with your new ProSafe One Ground Wire
and Galvanic Isolator Monitor, call us at 1-800-824-0524 for technical support.
If a replacement unit is needed, during warranty period ProMariner will ship a replacement
at no cost with a prepaid UPS shipping label for the original unit to be returned.
Maintenance
The ProSafe One Ground Wire and Galvanic Isolator Monitor is self contained and should
need no service. Periodically check all connections are tight, clean and free of moisture.
Using The ProSafe One Monitor Continued
Note: With any of the above faults present, and because of the possibility of high AC voltage
on the bonding system, it is highly recommended that the vessel's shore cord be disconnected
until a marine technician can determine and repair the fault.
To Silence the Audible Alarm:
In the event of a "FAIL" condition, if it is preferred to be able to use your 110/220 volt systems
without the presence of the audible alarm it can be silenced by holding the "TEST" button until
the alarm silences. The alarm will stay silent while leaving the "FAIL" LED illuminated. This does
not rectify the "FAIL" condition, and it is imperative that the reverse polarity condition, ground
wire or isolator be checked for a fault and the fault be repaired.
PN. 22079
Single AC Monitor
NOTES:
1. PN. 22115 Remote Monitor Extension Cable - 3 meters
N
6 ga.
PN. 22033
30 amp isolator
L1
MAIN Breaker
Green
Blue
Brown
PN. 22113 - 10 meter
PN. 22112 - 7 meter
PN. 22110 - 1 meter Isolator Cable
PN. 22111 - 4 meter
PN. 22075
Remote Display
NOTE 1
30 amp
ProSafe1
Shore Cable
Green
Bulkhead
Connector
AC Ground Bus
30 amp
30 amp
AC Ground Bus
MAIN Breaker
L1
Brown
Blue
Green
6 ga.
PN. 22066
60 amp isolator
L2
Blue
Green
Brown
MAIN Breaker
PN. 22080
Dual AC Monitor
NOTE 1
PN. 22075
Remote Display
PN. 22111 - 4 meter
PN. 22110 - 1 meter Isolator Cable
PN. 22112 - 7 meter
PN. 22113 - 10 meter
N
N
NOTES:
1. PN. 22115 Remote Monitor Extension Cable - 3 meters
ProSafe1
Shore Cable
Green