Janus – NORSTAT Safety Light Curtains,Safety Controllers User Manual
Page 10
8
http://muting.reer.it
JANUS MI TRX, MI TRXL
Janus MI TRX and MI TRXL consist of one active emitter/receiver element and one retro-reflecting
passive element which does not need electrical connections.
▪Models MI TRX with M12 front connectors for external Muting sensors with 2 or 4-sensor
logics for both two-way entry/exit (2 – 4 sensors) and one-way (2 sensors) exit only.
▪Models MI TRXL with single connector M23 with 2-sensor logics for two-way entry/exit (2
sensors)
▪2 - 3 - 4 beams for detection of the body in access monitoring
▪Max range 6 m.
JANUS ML TRX, ML TRX G
Janus ML TRX and ML TRX G, 2 or 3 beams for access monitoring have an original 2-horizontal
arms system – one for active side and one for passive side – with built-in Muting photoelectric
sensors, prewired and prealigned.
Models ML TRX G are designed to ensure reliable detection of glass and other transparent
materials.
Both light grid and Muting sensors consist of one active emitter/receiver element and one
retro-reflecting passive element which does not need electrical connections.
▪One-way Muting logics, exit only
▪2 and 3 beams for detection of the body in access monitoring
▪Max range 3,5 m models TRX (2 m TRX G)
▪Optoelectronic Muting sensors with 2 parallel beams.
JANUS MT TRX, MT TRX G
Janus MT TRX and MT TRX G, 2 or 3 beams for access monitoring have an original 4-horizontal
arms device (2 for active side and 2 for passive side) with built-in Muting photoelectric sen-
sors, prewired and prealigned.
Models MT TRX G are designed to ensure reliable detection of glass and other transparent
materials.
Both light grid and Muting sensors consist of one active sensor emitter/receiver and one retro-
reflecting passive sensor which does not need electrical connections.
▪Two-way Muting logics, entry/exit
▪2 and 3 beams for detection of the body in access monitoring
▪Max range 3,5 m models TRX (2 m TRX G)
▪Optoelectronic Muting sensors with 4 parallel beams.
Models ML, ML TRX and ML TRX G and MT, MT TRX and MT TRX G are quick and easy to install. Also, they are complying with
regulatory requirements on Muting sensor geometry and all other safety-related parameters, as per IEC TS 62046 and other
current standards.
Active
Passive
Active
Passive
Active
Passive
JANUS
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866
Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com