beautypg.com

MXL 992 User Manual

Marshall electronics, inc

background image

Marshall Electronics, Inc.

Product Innovation Through Technical Excellence!

1910 East Maple Ave. El Segundo, CA 90245

Phone: (310) 333-0606 Fax: (310) 333-0688 E-Mail:[email protected]

Internet:

www.MXLmics.com

Thank you for purchasing the MXL 992 Condenser microphone. With proper care, this mic will provide
many years of satisfaction. For best results, please take a few moments to review this literature.

General Characteristics
This microphone has a twenty-five millimetre gold-sputtered diaphragm and a fixed cardioid pickup pattern.
Condenser microphones are very sensitive, readily revealing very subtle sonic details. They also tend to
pick up sounds outside the pattern more than some designs, which can lead to powerful feedback if you are
not careful. We strongly advise experimentation with placement and isolation requirements with the gain
initially set low to avoid equipment (and ear) damaging surprises!

Power Requirements
IMPORTANT - This unit requires phantom power at 48 volts, +/- 4 volts. Each unit has been thoroughly
checked before shipping, so if you hear no sound, check that the phantom power on your mixer or separate
power supply is switched on!

Microphone Cables
The microphone cable can have a profound effect on the sound of any microphone.

Even the finest

microphones will sound poor if the interconnect cable allows noise to enter, or causes distortion and loss of
information. Use only the best microphone cable your budget will allow.

Care
Dust and foreign material can degrade the performance of a microphone over time so always store the unit
in its case. Remove fingerprints from the exterior with a damp soft cloth. Clean the gold contacts
occasionally with a de-oxidant/cleaner. For vocals use a “popper stopper” or a foam windscreen to avoid
getting moisture on the diaphragm as this can substantially degrade the microphone’s performance.

Data
Type:

25mm, Six micron condenser pressure gradient diaphragm

Frequency Response:

20-20 KHz

Polar Pattern:

Cardioid

Sensitivity:

15mV/pa

Output Impedance:

200 ohms

Max SPL:

130 dB , 140 dB w/-10dB cut

S/N Ratio:

80dB (Ref. 1 PA, A weighted)

Equivalent Noise Level: 10dB (A weighted IEC 268-4)
High Pass Filter:

6dB/octave, 150HZ (Internal switch)

Preattenuation Switch:

0/-10dB

Power Requirement:

48V phantom power (+- 4V)

Size:

60mm x 130mm

Weight:

2 lbs.

Metal Finish:

Champagne

Warranty
Marshall microphones are guaranteed against defects in material and workmanship for Three years from
date of purchase. Should you encounter any problem with this unit, promptly contact the company you
purchased it from for assistance. The original dated sales receipt will be necessary for any warranty claim.
Do not send any unit directly to us without prior authorization from our service department! Warranty
coverage is limited to repair or replacement (at our option) of the microphone, and does not cover incidental
damages due to use of this unit, nor damage caused by accidental misuse of this product.