Ordering information, Specifications, Common specifications – Adam Equipment Adam-4000 User Manual
Page 11: Robust 8-ch thermocouple input module with modbus

www.advantech.com/products
Online Download
4-11
8
5
44
10
CompactPCI
9
Plug-in I/O
8
AWS
7
FPM
6
IPPC
TPC
RS-485 I/O
3
UNO
2
BAS
1
PAC & Software
11
Signal Conditioning
12
USB I/O
13
Motion Control I/O
14
Ethernet Switch
15
EDG
16
ICOM
17
Ethernet I/O
Ordering Information
ADAM-4118
Robust 8-ch
Thermocouple
Input Module with
Modbus
®
ADAM-4150
Robust Digital
I/O Module with
Modbus
ADAM-4168
Robust Relay
Output Module with
Modbus
Specifications
General
Power Consumption
0.5W @ 24 V
DC
Analog Input
Channels
8 differential
and independent
configuration channels
Input Impedance
Voltage: 20 M
Ω
Current: 120
Ω
Input Type
T/C, mV, V, mA
Input Range
Thermocouple
J 0 ~ 760 °C
K 0 ~ 1370 °C
T -100 ~ 400 °C
E 0 ~ 1000 °C
R 500 ~ 1750 °C
S 500 ~ 1750 °C
B 500 ~ 1800 °C
Voltage mode
±15 mV, ±50 mV,
±100 mV, ±500 mV,
±1 V, ±2.5 V
Current mode
±20 mA, 4 ~ 20 mA
Accuracy
Voltage mode: ±0.1% or
better
Current mode: ±0.2%
or better
Resolution
16-bit
Sampling Rate
10/100 samples/sec
(selected by Utility)
CMR @ 50/60 Hz
92 dB
NMR @ 50/60 Hz
60 dB
Overvoltage Protection ±60 V
DC
High Common Mode
200 V
DC
Span Drift
±25 ppm/° C
Zero Drift
±6μV/° C
Built-in TVS/ESD Protection
ADAM-4118
ADAM-4118
ADAM-4150
ADAM-4168
Robust 8-ch Thermocouple Input Module
with Modbus
®
Robust Digital I/O Module with Modbus
Robust Relay Output Module with Modbus
ADAM-4150
ADAM-4168
Specifications
General
Power Consumption
0.7 W @ 24 V
DC
Digital Input
Channels
7
Input Level
Dry contact:
Logic level 0: Close to
GND
Logic level 1: Open
Wet contact:
Logic level 0: +3 V max
Logic level 1: +10 V to
+30 V
(Note: The Digital Input Level 0 and 1 status can be
inverted)
Support 3 kHz Counter Input (32-bit + 1-bit
overflow)
Support 3 kHz Frequency Input
Support Invert DI Status
Digital Output
Channels
8, open collector to 40 V
(1 A max. load)
Power Dissipation
1W load max
Ron Maximum
150 m
Ω
Support 1 kHz Pulse Output
Support High-to-Low Delay Output
Support Low-to-High Delay Output
Specifications
General
Power Consumption
1.8 W @ 24 V
DC
Relay Output
Output Channels
8 Form A
Contact Rating
AC: 0.5 A @ 120 V
(Resistive)
0.25 A @ 240 V
DC: 1 A @ 30 V
0.3 A @ 110 V
Breakdown Voltage
750 V
AC
(50/60 Hz)
Initial Insulation
1 G
Ω min. @ 500 V
DC
Resistance
Relay Response Time On: 3ms
(Typical)
Off: 1ms
Total Switching Time 10 ms
Supports 100 Hz pulse output
Common Specifications
Power Input
Unregulated 10 ~ 48 V
DC
Watchdog Timer
System (1.6 second) &
Communication
Connector
2 x Plug-in terminal
blocks (#14 ~ 22 AWG)
Isolation Voltage
3000 V
DC
Support Protocol
ASCII Command and
Modbus/RTU
Environment
Humidity
5 ~ 95% RH
Operating Temperature -40 ~ 85 °C
(-40 ~ 185° F)
Storage Temperature -40 ~ 85°C
(-40 ~ 185° F)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com