FEATURES AND SPECIFICATIONS
FEATURES
Welded steel epoxy-coated flow tube
Flanges, ANSI 150 lb. drilling
HDPE liner
Power/Output cable port access
Equalization lug
Diecast-aluminum electronics housing
Rate and total indicator
316SS electrodes
WMX104 Shown
4”, 6”, 8”, 10”
ANSI 150 lb. drilling
150 psi working pressure
10° F to 130° F
+/-1% of reading from 10% to 100% of full scale
+/-2% of reading from cut off to 10% of full scale
Welded steel, epoxy powder coated
HDPE
Diecast aluminum
316 stainless steel
Rate
Total
6
8
Gallons/Minute
Gallons x 1000
Million Gallons/Day
Gallons x 1000
Liters/Second
Cubic Meters
Liters/Second
Megaliters
Cubic Feet/Minute
Cubic Feet
WMX101: 7-26 Vdc at 30 mA max, with battery backup for continuous operation during power failures
(See WARNING on wiring diagrams)
WMX104: 2 Lithium 3.6V “D” batteries, replaceable, 3 year life
WMX101: Current sinking pulse, opto-isolated, 24 Vdc at 10 mA max
WMX104: Pulse output available only with addition of post-factory output cable
Hardware/software, conductivity-based
NEMA 4X
Pipe Sizes
Flanges
Pressure
Temperature Range
Accuracy
Materials
Body
Liner
Electronics Housing
Electrodes
Display
Digits
Units*
Power
Output Signal
Empty Pipe Detection
Environmental
SPECIFICATIONS
*Consult factory for additional units
WMX101 comes
with cable installed
FLOW RANGE
4”
6”
8”
10”
Gal/Min Liter/Sec
Gal/Min Liter/Sec
Gal/Min Liter/Sec
Gal/Min Liter/Sec
12
.75
32
2
60
3.8
95
6
500
31.5
1,200
75.7
2,200
138.8
3,500
220.8
Minimum
Maximum
AR
CH
IVE
D
(January 2008)