Seametrics FT500B User Manual
Dis con tin ued
PUB -19096-1000
Page 1 of 4
Features
FT500B
FLOW COMPUTER
Batch Status Indicator
Wide variety
of units
Simple display eases
descriptive
programming
Hinged door cover
for protection
Removes for
easy access
Simple four-key
programming
Sealed external
control buttons
General Information
The FT500 Batch Control is a microprocessor-based
unit which displays rate, batch count, and running total,
and has output functions which can be used for control
or remote monitoring. These include two batch relays
(primary and prewarn) and programmable pulse, for
telemetry and pump pacing.
A large alphanumeric display makes reading easy, and
menu-based programming eliminates the need to
memorize numeric codes. Display units, high/low alarm
settings, pulse output, and meter factor are some of the
programmable features.
The FT500B is housed in a weathertight enclosure with
hinged clear cover. Terminal access is made simple by
a separate terminal compartment cover. Optional meter
input connectors can be ordered for plug-in meter
connection.
Specifications
Power 115 VAC, 12 VDC optional
Temperature 32
°
- 130
°
F
Enclosure Non-metallic, NEMA 4X
Outputs Two Form-C SPDT relay
Max. Output Load 3 A at 115 VAC
Sensor Power 12 - 16 VDC, 50 mA
Max. Cycle Size 999,999 units
Max. Output Time 9,999 seconds
Total Display Eight-digit, resettable
Rate Display Five-digit
Sensor Frequency 500 Hz maximum
FT500B
Batch Controller
Instructions
DIS
CON
TIN
UED