Seametrics FT400 User Manual

Dis con tin ued

background image

Features

FT400 Flow Computer

Instructions

PUB -19081-1095

Page 1 0f 4

Power 11-28 VDC, 20mA max.

24-28 VDC

Flow Sensor Power 8 Volts DC, 50 mA maximum
Temperature 0

°

C to 70

°

C

Display Custom 8-digit LCD,

0.4" digits

Totalizer 8-digit resettable

(non-reset optional)

Rate Indication 8-digit with autorange
K Factor Range .050 - 1999.999
Pulse Output Range 0.1 - 99,999.9 gallons per

pulse

Pulse Output 0.1-second open-collector

transistor, 100 mA, 60 VDC
maximum

Analog Output
(Optional)
4-20 mA isolated 24 VDC, 500

Ohm maximum

Analog Output
Resolution
500 counts full scale
Sensor Output 100 mA, 60 VDC maximum

Specifications

General Information

The SeaMetrics FT400 is a compact digital flow monitor
with user-programmed output features. Combined with
an IP Series insertion flow sensor or a WT turbine meter,
it is ideal for flow rate and total indication, chart record-
ing, and proportional chemical feed. It is available in wall
or panel-mount enclosures, or in a round cast-aluminum
housing mounted directly on a SeaMetrics meter. For
wall-mounting, the non-metallic enclosure is splashproof
and has a clear cover. The housing for panel mounting
is standard 1/4 DIN-sized, with gasketed front panel and
membrane switches.

An eight-digit totalizer is resettable, unless ordered with
non-reset option. Programming prompts simplify set up
by indicating the next step. Pulse output is a program-
mable 0.1 second open-collector transistor pulse, which
is compatible with electronic metering pumps, PLC's,
computer input cards, and SeaMetrics controls. An op-
tional 4-20 mA output feature is front-panel program-
mable in standard flow rate units.

RESET RATE/TOTAL

+

PROGRAM

-

FT400

SET P

400.0

Reset Totalizer to Zero
(Non-resettable optional)

Switches between Rate and
Total Displays (Also responds to
magnet outside enclosure)

Selectable
decimal
point

Press to change
settings:

K-factor

Pulse Output

4-20 mA(optional)

Prompts appear
when program
button is pushed.
"SET P" means
set pulse output
in gallons per
pulse.
Other prompts:

SET K (meter factor)

SET 20 mA(optional)

SET DP(totalizer)

Buttons increase
or decrease setting

Seaflow

DIS

CON

TIN