The EM100 can be supported by its piping connections
if the piping is rigid and there is no vibration.
Alternatively, the grounding studs can be used for
mounting by inserting them through pre-drilled holes.
Note the centerline distance in the dimensional
drawing below.
INSTALLATION
.83
.62
5.70
2.48
L
3.75
2.00
2.000
.60
6 FT. LONG
CONTROL CABLE,
6 CONDUCTOR
12 FT. LONG GROUNDING
WIRE WITH LUGS (SUPPLIED)
2 EACH #10 LOCKWASHERS
& #10-24 HEX NUTS (SUPPLIED)
#10-24 STUDS (2), 316
ABS HOUSING
-025
-038
-050
3/8 NPT
3/8 NPT
1/2 NPT
Size
Fittings
L (Length)
3.75
3.75
4.90
Table 1: Fittings and Length
MALE PIPE FITTING,
PVDF PLASTIC,
2 PLACES;
SEE TABLE 1
CAUTION:
Although this meter has
an empty pipe detection function,
under certain conditions of empty
or partially-full pipe the meter may
read a flow when there is none.
If this is a hazardous condition,
mount the meter in such a way as to ensure the meter
will always be full of liquid.
MOUNTING
EM 100/102 SERIES
MAGNETIC FLOW METER INSTRUCTIONS
www.seametrics.com