TROuBLEShOOTinG
Problem
Probable cause
Try...
Laptop screen reads
”No connection,” but
“Active” light is NOT
blinking
Laptop screen reads
”No connection,” but
“Active” light IS blinking
Flow rate incorrect
No flow rate
DL75 is transmitting data.
Wait two minutes before taking action.
Dead battery in DL75
Loose cable
Bad cable
K-factor setting is incorrect
Damaged flow sensor
Broken wire
Wait for “Active” light to blink
Replace battery
Tighten cable
Replace cable
Make sure K-factor in DL75 matches flow
sensor
Mechanical: See if rotor spins freely
EX Magmeter: See if “Status LED” indicator
is blinking
Check for flow rate