QUICK START REFERENCE

Use this section for reference - please read all safety instructions and

appropriate manual sections for installation and operation instructions.

• Do NOT add chemicals to feeders until all start-up operations are completed.

• Manually adjust and balance pool/spa to acceptable levels and verify using DPD test kit

prior to start-up. Automation should be used to maintain chemical levels, not to balance a
pool/spa that is out of acceptable chemical ranges.

On/Off:

• press the mode button to turn the unit on.

note: ‘FLOW’ light must illuminate.

• press and hold the mode button to turn the unit off.

“OFF” will be displayed in the windows

To Operate:

• press and release the mode button until the “AUTO” light is lit.

Unit will now operate in the factory preset settings:
- Set level: pH = 7.4
- Feed times: 0.6 second feed with a 5 minute delay
- Limits/Alerts: pH; 8.0 hi, 7.0 low

To Change Settings:

• Press and release the mode button –AUTO light off.

Note: Once the settings are changed, they will remain at those settings until they are
manually changed.

Set Level: press the Set Level button until the desired set point is reached.
Feed Time: press the Feed Time button until the desired feed time is reached.
The number represent the seconds of feed time
(all with 5 minute delays).
Range is 0.6 to 900 sec. (15 min.).
Constant feed is ‘con’.

Other: See the appropriate manual sections for:

• calibrating the pH sensor

• changing function (acid/base feed)


Rola-Chem Digital Controller PN 554212 6/01/2012 Page: 2 of 12