beautypg.com

Precision Control Systems DryIR 6040 User Manual

Page 17

background image

Model 6040 Dry IR Drying System Instruction Manual

Figure A-1. Model 6040 Dimensions.

Maximum Drying Width

4 inches (102 mm)

Overall Length

15 inches (381 mm)

Heated Length

10 inches (254mm)

Lamps (4 Total)

1000W-Rapido-COLL-14OAL

Lamp Rated Voltage

240 volts

Applied Lamp Voltage

240 volts

Amps at Applied Voltage

18.0 amps

KW at Applied Voltage

4.0 KW

Blower Air Volume

75 CFM (2.1m³/min)

Interlock Relays

120 VAC, 24 VAC, 24VDC

Mounting Hardware

Extruded Aluminum

Operator Controls

On/Off switch
Heat Adjustment
Automatic Heat Adjustment via Tachometer Input
Circuitry and External Tachometer Kit
(Tachometer Kit Option – ordered separately from
Drying System)

Operation Interrupts

When the interlock connections are made, the heater
module will not function unless the transport is
running

Site Requirements

240VAC/30 amp 1

φ service dedicated circuit.

Personnel to position the system in place
An electrician to install a 240VAC/30 amp IEC power
cord, and connect the wiring between the power
control and the transport.

Table A-1. Model 6040 Dry-IR Specifications.