Section 1 - Introduction


The Model C100 cooling system is designed to provide water-cooling for small Research
Inc. aluminum-reflector heaters. The photograph to the left shows the C100 providing
cooling for a Model 5305 heater. (Note: Heater and lamp are sold separately.) The unit
includes a self-contained pump, coil, blower unit, and 6 gallon (23 liter) reservoir. A kit with
quick disconnect fittings is available to provide cooling requirements for the following
heaters:

StripIR

®

5305 / 5306 (all sizes)

LineIR

®

5193 / 5194 (all sizes)

ChambIR

®

E4 (up to 10 inch lamp – may require 2 – C100 units)



Figure 1 - C100-120 with 5305 Heater

A water/glycol mixture is circulated through the closed system. As the liquid is heated as it
passes through the heater. The liquid is cooled by the self-contained blower/coil unit in the
C100. The C100 kit comes with quick disconnect fittings and plastic tubing for quick
installation and maintenance.

Research, Inc. • USA • Ph: 952.949-9009 • Fax: 952.949-9559•

[email protected]

www.researchinc.com