1 scope of the document, 2 device description, 3 scope of delivery – KROHNE OPTIWAVE 6300C PROFIBUS PA User Manual
Page 3: General safety information
GENERAL SAFETY INFORMATION
1
3
OPTIWAVE 6300 C
www.krohne.com
02/2010 - 4000621201 - AD PROFIBUS PA OPTIWAVE 6300
1.1 Scope of the document
These instructions are applicable only to the radar level transmitter with the PROFIBUS PA
communication option. For all other data, use the Quick Start and other chapters of the
Handbook. If you do not have these documents, please contact the nearest office or download
them from the manufacturer's internet site.
1.2 Device description
This device is a 4-wire level transmitter that uses FMCW (Frequency-Modulated Continuous
Wave) radar technology. It measures level, volume, distance to surface, and reflectivity of solid
particles, granulates and powders.It is suitable for installation on storage tanks and silos.
Measurements are displayed via a DTM (device type manager) for remote communication or on
an optional integrated display screen with wizard-driven setup and online help functions.
The level transmitter is approved for use in potentially explosive atmospheres when equipped
with the appropriate options.
1.3 Scope of delivery
The information in this chapter only contains the data applicable to PROFIBUS PA
communication. The technical data in the Handbook shall be valid in its current version, provided
that it is not rendered invalid or replaced by this supplement.
A device for PROFIBUS PA communication is supplied with
• Supplementary Instructions for PROFIBUS PA communication
• PROFIBUS device data files (GSD)on a CD-ROM supplied with the device
INFORMATION!
The information in this chapter only contains the data applicable to PROFIBUS PA
communication. The technical data in the Handbook shall be valid in its current version, provided
that it is not rendered invalid or replaced by this supplement.