ADDENDUM

2

5

OPTIWAVE 5200 C/F

www.krohne.com

12/2013 - 4003298801 - AD cFMus OPTIWAVE5200 R01 en

2.1 System design

There are 2 seals in the housing:

• The primary seal

primary seal

primary seal

primary seal at the bottom of the housing. This is a wetted part that is made of FKM/FPM,

Kalrez

®

6375, EPDM or PFA. The primary seal material used depends on the options selected

in the customer order.

• The secondary seal

secondary seal

secondary seal

secondary seal between the the electronics block compartment and the terminal / user

interface compartment.

2.2 Operating principle

An annunciation

annunciation

annunciation

annunciation (pressure relief) valve

valve

valve

valve is attached to one of the cable entries on the housing. It

has a red indicator that shows if the primary seal is damaged.

The valve opens when there is a difference of more than 1 bar / 14.5 psi between the pressure
inside the electronics block compartment and atmospheric pressure. The annunciation valve has
2 positions:

WARNING!
Make sure that the process fluid in the tank is compatible with the primary seal material.

INFORMATION!
No maintenance is necessary.
The device is supplied with the annunciation valve in its "CLOSED" position. Inspect the
annunciation valve carefully for damage or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.

Annunciation

valve position

Relative pressure in the

electronics block compartment

Condition

[psi]

[bar]

Closed

< +14.5

< +1 The red indicator is in. The primary seal is in

good condition. The device is safe to use.

The red indicator is in. Possible failure of the
primary seal. The process fluid is in the housing
but cannot flow out of the valve. The device is
safe to use.

Open

> +14.5

> +1 The red indicator is out. Failure of the primary

seal. The process fluid is in the housing and can
flow out of the valve.