KROHNE LS 72xx EN User Manual
Page 8
02/2013
LS 72xx
8
Wire break
Sensitivity too low
Insufficient electrode area
connections
Select higher sensitivity
Strip more insulation from
electrode
Constant level indication
Short-circuit to ground, sensor
Short-circuit
Sensitivity too high (possibly
deposits)
Replace sensor
Check power leads, power
cable
Select lower sensitivity
With integrated level converter module
LED not “on”
Supply voltage < 18 V
Measure voltage at pin 1, 2
No switching output
Wire break
Supply polarity incorrect
Short-circuit
Check continuity of wires
Reverse terminals 1, 2
Check wiring
4
Technical data
4.1
Technical data table
Connection head
Stainless steel V2A 1.4305; 55 mm dia.
Electrical connection
Cable gland M16; M12 connector
Process connection
Threaded socket G1/2“h; V4A 1.4571
Type of protection
IP 67
Insulating part
PEEK
Electrode
4 mm dia.; V4A 1.4571
(Option: PTFE coating)
Ambient temp. range
–20...+60 °C
Process temp. range
–20...+140 °C
Operating pressure
max. 16 bar
Mounting position
Rod electrode: above; stub electrode: any
With integrated level converter module
Indicating elements
1 LED red (level)
Power supply
18...36 V DC; 10 mA max. (no load switched)
Output
min. Ub – 1 V, (50 mA max. short-circuit-proof)
Switching function
full / empty polarity of supply power
Response time
Damping 0.5 s
Sensitivity
200
Ω, 2 kΩ, 20 kΩ via control signal
With electrode output for level converter module
Output electrode
connection, ground connection