Connect L1 and L2 to the power block and ground to the copper lug located in the rear service box
mentioned on the previous page.

If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/
pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the
service breaker panel. In both cases, a strain relief must be installed where the wiring enters the
dryer.

b. 3-Phase (3ø) Wiring Connections (Hookup) - For Non-Reversing Models Only

The electrical connections on ALL 3-phase (3ø) gas model dryers are made into the rear service box
located at the upper left area of the dryer.

NOTE: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.

If local codes permit, power to a gas dryer can be made by the use of a flexible U.L. listed power cord/
pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service
breaker panel. In ALL cases, a strain relief must be installed where the wiring enters the dryer.

S

INGLE

-P

HASE

(1

Ø

)

E

LECTRICAL

C

ONNECTIONS

L

EADS

Black

+

Positive

White

-

Neutral

Green

Ground

or