Ifc090 menu tree ams – KROHNE IFC 090 Converter HART User Manual
Page 8
KROHNE Messtechnik GmbH & Co. KG · Ludwig-Krohne-Str. 5
! D-47058 Duisburg
8/8
Tel.: 0203-301 0
! Fax: 0203-301 389 · e-mail: [email protected]
Remote Operation Instructions IFC090 HART
Attachment B
(continued from the previous page)
Loop test
Test measuring range
-----------------------------
Hardware information
Quit/view errors
IFC090 Menu Tree AMS
Process Variables
Status
Scan Device
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Reset totalizers
Stop/resume totalizers
Set/reset password
-----------------------------------
Audit Trail
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties
Zero trim
Apply values
-------------------------------
Calibration Management
Basic Setup
•
Hardware
Rd
•
Tag
--------------------------------
•
Upper Sensor Limit
Rd
•
Sensor Minimum Span
Rd
--------------------------------
•
Time Constant
•
Flow Units
--------------------------------
•
Full Scale Value
•
Flow Min
Rd
•
Damping Control
--------------------------------
•
Terminal B1
Opt
•
Terminal B2
Opt
Sensor
•
PV Sensor serial num
•
Diameter
•
GK Value
•
Flow Direction
--------------------------------
•
Upper Sensor Limit
Rd
•
Sensor Minimum Span
Rd
--------------------------------
•
Application
•
Field Frequency
•
Line Frequency
--------------------------------
•
ADC firmware Id
Rd
•
I/O firmware Id
Rd
•
Display firmware Id
Rd
Analog Output
•
Function I
•
Rev.Range Control
•
Rev.Range Scale
•
I 0%
•
I 100%
•
I Max
•
I Error
--------------------------------
•
AO Alarm type
Rd
--------------------------------
•
Function P
Opt
•
Pulse Type
Opt
•
Pulse Control
Opt
•
Pulse Width
Opt
•
Pulse Value
Opt
--------------------------------
•
Cutoff Control
•
Cufoff ‘On’ value
•
Cutoff ‘Off‘ value
Device
•
Model
Rd
•
Manufacturer
Rd
•
Field device revision
Rd
•
Hardware revision
Rd
•
Software revision
Rd
•
Write protect
--------------------------------
•
Empty Pipe
Opt
--------------------------------
•
Terminal B1
Opt
•
Terminal B2
Opt
--------------------------------
•
Text Volume
•
Text Time
•
Factor Volume
•
Factor Time
HART
•
Tag
•
Device Id
Rd
•
Final assembly num
•
Date
•
Descriptor
•
Message
--------------------------------
•
Universal revision
Rd
•
Num request preams
Rd
•
Num response preams
•
Polling address
Binary I/O
•
Terminal B1 Function
Opt
•
Terminal B2 Function
Opt
--------------------------------
•
Trip.Point 1, Low
•
Trip.Point 1, High
•
Trip.Point 2, Low
•
Trip.Point 2, High
•
Auto/External Range
Designations:
Opt
– Optional variable, depends on device implementation:
availability of Binary Terminals B1/B2 and their assignment,
etc.;
Rd
– Read-only variable;
Loc
– Local AMS variable, affects only AMS faceplates and
configuration tabs and is not read/written from/to instrument.
Process Input
•
Flow Units
•
Totalizer Units
•
Pulse Value Units
•
Time Constant
--------------------------------
•
Flow format
Loc
•
Totalizers’ format
Loc
•
Pulse Value format
Loc
KROHNE IFC090 45f40201