2.7 Ambient temperature / temperature classes

Because of the influence of the temperature of the product, no fixed temperature class is
assigned to variable area flowmeters. In fact, the temperature class of a device is a function of
the temperature of both the product and the environment. There is no distinction between
devices with one or two contacts. The classification is outlined in the following tables.

The tables take into account the following parameters:

• Ambient temperature T

amb.

• Product temperature T

m

DK3./../.././../A–Ex permissible medium and ambient temperatures

INFORMATION!

The maximum permissible product temperatures listed in the tables are valid under
the following conditions:

The measuring device is installed and operated in accordance with the installation
instructions in the installation and operating manual.

It must be ensured that the flowmeter is not heated by the effects of additional heat radiation
(sunshine, neighbouring system components) and thus operated above the permissible
ambient temperature range.

Insulation must be limited to the piping.
Unobstructed ventilation of the indicator part must be ensured.

Temperatur

e class

Ambient

temperature

Maximum permitted product temperature

with plug (P) or cable entry (C)

Type DK32

Type DK34

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6

-25...+40

-13...+104

75

167

80

176

-25...+50

-13...+122

70

158

70

158

-25...+60

-13...+140

60

140

60

140

T5

-25...+40

-13...+104

100

212

100

212

-25...+50

-13...+122

95

203

100

212

-25...+60

-13...+140

85

185

90

194

T4

-25...+40

-13...+104

135

275

135

275

-25...+50

-13...+122

130

266

135

275

-25...+60

-13...+140

120

248

130

266

-25...+90

-13...+194

90

194

90

194

T3...T1

-25...+40

-13...+104

135

275

150

302

-25...+50

-13...+122

130

266

140

284

-25...+60

-13...+140

120

248

130

266

-25...+90

-13...+194

90

194

90

194

AD_DK32_34_NEPSI_Ex_nA_R01_en_4002598301_PRT.book Page 6 Wednesday, May 22, 2013 2:26 PM