background image

Screw terminals

for wire cross-section up to 1.5 mm²

(0.0023 in²)

Adjustment elements
Mode switch
- A

Max. detection or overflow/overfill protection

- B

Min. detection or dry run protection

Density switch
- 0.5

0.5 … 2.5 g/cm³ (0.018 … 0.9 oz/in³)

- 0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

Voltage supply
Supply voltage

20 … 253 V AC, 50/60 Hz, 20 … 253 V DC

Domestic current requirement

approx. 3 mA (via load circuit)

Load current
- min.

10 mA

- max.

400 mA (with I> 300 mA the ambient temper-

ature can be max. 60 °C) max. 4 A up to 40 ms

(not WHG specified)

Electrical protective measures
Protection

IP 66/IP 67

Overvoltage category

III

Protection class

I

Approvals

1)

ATEX II 1/2G, 2G EExd d IIC T6

2)

Overfill protection acc. to WHG
Ship approvals

1)

Deviating data in Ex applications: see separate safety instructions.

2)

Only with Aluminium housing.

Supplement

28

OPTISWITCH 5100 C, 5150 C - with contactless electronic switch

30428

-EN
-060831