The vibrating level switch is a measuring instrument and must

be treated accordingly. Bending the vibrating element will

destroy the instrument.

Warning:

The housing must not be used to screw in the instrument!

Applying tightening force on the housing can damage its

internal mechanical parts.
To screw in, use the hexagon above the thread.

4.2 Mounting instructions

Agitators, equipment vibration, etc., can cause the level switch

to be subjected to strong lateral forces. For this reason, do not

use an overly long extension tube for OPTISWITCH 3300 C,

but check if you can mount a short level switch on the side of

the vessel in horizontal position.
Extreme vibration caused by the process or the equipment, e.

g. agitators or turbulence in the vessel e.g. from fluidization,

can cause the extension tube of OPTISWITCH 3300 C to

vibrate in resonance. This leads to increased stress on the

upper weld joint. Should a longer tube version be necessary,

you can provide a suitable support or guy directly above the

tuning fork to secure the extension tube.

This measure applies particularly to applications in Ex areas.

Make sure that the tube is not subjected to bending forces

through this measure.

If OPTISWITCH 3300 C is mounted in the filling stream,

unwanted switching signals may be generated. Mount OPTI-

SWITCH 3300 C at a location in the vessel where no disturbing

influence from e.g. filling openings, agitators etc. can occur.
This applies particularly to instrument types with long

extension tube.

Handling

Agitators and fluidization

Inflowing medium

OPTISWITCH 3300 C - with two-wire output