9 Supplement

9.1 Technical data

General data
Materials, wetted parts
- Process fitting

thread G2A and 2 NPT: PVDF

- Transducer

PVDF

- seal transducer/thread

EPDM

Materials, non-wetted parts
- Housing

plastic PBT (Polyester), Alu-die casting pow-

der-coated, 316L (1.4435)

- Seal ring between housing and

housing cover

NBR (stainless steel housing), silicone (Alu/

plastic housing)

- Inspection window in housing cover

Polycarbonate

- Ground terminal

316Ti/316L (1.4571/1.4435)

Weight

1.8 … 4.0 kg (4.0 … 8.8 lbs), depending on

process fitting and housing

Max. torque mounting boss

25 Nm

Output variable
Output signal

4 … 20 mA/HART

Resolution

1.6 µA

Fault signal

current output unchanged; 20.5 mA; 22 mA;

<3.6 mA (adjustable)

Current limitation

22 mA

Load

see load diagram in Power supply

Integration time (63 % of the input

variable)

0 … 999 s, adjustable

Fulfilled NAMUR recommendation

NE 43

Input variable
Parameter

distance between lower edge of the transducer

and product surface

Dead zone

0.4 m (1.3 ft)

Measuring range
- Liquids

up to 8 m (26.2 ft)

- Solid

up to 3.5 m (11.5 ft)

38

OPTISOUND 3020 C - 4 … 20 mA/HART

Supplement

30507

-EN