2

DEVICE DESCRIPTION

6

DK32 DK34

www.krohne.com

03/2013 - 4002148602 AD DK32/34 II3G R03 en

2.6 Protection types

Variable area flowmeters can be operated as protection type "non-sparking" or "intrinsic safety
protection level ic". Explanations of the individual protection types appear below.

The variable area flowmeter is designed with protection type "non-sparking" in accordance with
EN 60079-15. Protection against explosion is ensured in that no sparking contacts or hot
surfaces lead to ignition under normal operating conditions.

The marking is: II 3G Ex nA IIC T6 Gc

II 3G Ex nA IIC T6 Gc

II 3G Ex nA IIC T6 Gc

II 3G Ex nA IIC T6 Gc

The variable area flowmeter is designed with protection type "intrinsic safety, protection level ic"
in accordance with EN 60079-11. The explosion protection is ensured by way of limiting the
current and voltage so that no energy capable of ignition can occur.

The marking is: II 3G Ex ic IIC T6 Gc

II 3G Ex ic IIC T6 Gc

II 3G Ex ic IIC T6 Gc

II 3G Ex ic IIC T6 Gc

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

II

IIII

II

Group II explosion protection

3333

Equipment category 3

G

G

G

G

Gas explosion protection

nA

nA

nA

nA

Non-sparking equipment

IIC

IIC

IIC

IIC

Gas groups IIA, IIB, IIC

T6

T6

T6

T6

Temperature classes T6 ... T1

Gc

Gc

Gc

Gc

Equipment protection levels (EPL)

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

The marking contains the following information:

II

IIII

II

Group II explosion protection

3333

Equipment category 3

G

G

G

G

Gas explosion protection

ic

ic

ic

ic

Intrinsically safe equipment, protection level ic

IIC

IIC

IIC

IIC

Gas groups IIA, IIB, IIC

T6

T6

T6

T6

Temperature classes T6 ... T1

Gc

Gc

Gc

Gc

Equipment protection levels (EPL)