Device description, 8 electrical data – KROHNE H250 M10 ATEX II2G Ex d EN User Manual

Page 8

background image

2

DEVICE DESCRIPTION

8

H250 M10

www.krohne.com

06/2012 - 4001058901- MA H250/M10-Ex-II2G-AD R02 en

Maximum permissible product and ambient temperatures per temperature class

The cable glands and line entries must have the same degree of thermal stability as the
connecting cable.

The minimum product temperature is -40°C / -40°F.

2.8 Electrical data

Temperature
class

Ambient
temperature

Product temperature at permanent service temperature
of connecting cable

70°C / 158°F

80°C / 176°F

90°C / 194°F

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6

-40...+60

-40...+140 85

185

85

185

85

185

T5

-40...+50

-40...+122 100

212

100

212

100

212

-40...+60

-40...+140 85

185

100

212

100

212

T4

-40...+50

-40...+122 135

275

135

275

135

275

-40...+60

-40...+140 85

185

135

275

135

275

T3...T1

-40...+40

-40...+104 180

356

200

392

200

392

-40...+50

-40...+122 135

275

190

374

200

392

-40...+60

-40...+140 85

185

145

293

200

392

Electrical equipment

Rated voltage

Nominal current

Signal output M10

24 VDC ± 30%

4...20 mA
with HART

®

communication

Binary outputs B1 and B2

8...30 VDC

max. 100 mA

Reset input

5...30 VDC

≤ 1 mA