beautypg.com

Installation – KROHNE OPTIFLUX 7300 Quickstart EN User Manual

Page 12

background image

2

INSTALLATION

12

OPTIFLUX 7300

www.krohne.com

01/2011 - 7312082200 - QS OPTIFLUX 7300 R02 en

EN 1092-1

ASME B 16.5

Nominal size

DN [mm]

Pipe flanges

Max. allowable torque with gaskets made of

Gylon

®

[Nm]

Chemotherm

®

[Nm]

25

PN 40

22

32

40

PN 40

47

66

50

PN 40

58

82

80

PN 40

48

69

100

PN 16

75

106

100

PN 25

94

133

Nominal size

DN [mm]

Pipe flanges

Max. allowable torque with gaskets made of

Gylon

®

[ftlb]

Chemotherm

®

[ftlb]

1"

150 lb

18

24

1 1/2"

150 lb

28

40

2"

150 lb

43

61

3"

150 lb

72

102

4"

150 lb

55

80

Nominal size

DN [mm]

Pipe flanges

Max. allowable torque with gaskets made of

Gylon

®

[ftlb]

Chemotherm

®

[ftlb]

1"

300 lb

15

21

1 1/2"

300 lb

32

45

2"

300 lb

45

64

3"

300 lb

43

61

4"

300 lb

63

90