beautypg.com

Installation – KROHNE OPTIFLUX 5000 Flange Quickstart EN User Manual

Page 13

background image

INSTALLATION

2

13

OPTIFLUX 5000

www.krohne.com

04/2011 - 7309872300 - QS OPTIFLUX 5000 FL R03 en

ASME B 16.5

DN150...300
Tighten the bolts:

• Step 1: approx. 50% of max. torque
• Step 2: approx. 80% of max. torque
• Step 3: 100% of max. torque given in table

EN 1092-1

ASME B 16.5

Nominal size

[inch]

Flange class

[lb]

Bolts

Max. torque

[ftlb]

1/2

300

4 Ч 1/2"

40

1

150 / 300

4 Ч 1/2"

40

1 1/2

150 / 300

4 Ч 1/2"

40

2

150 / 300

4 Ч 5/8"

97

3

150 / 300

4 Ч 5/8"

97

4

150

8 Ч 5/8"

97

Nominal size

DN [mm]

Pressure

rating

Bolts

Max. torque

[Nm]

150

PN 16

8 × M 20

1

200

PN 10

8 × M 20

1

250

PN 10

12 × M 20

1

300

PN 10

12 x M 20

1

1 Max. torque depends on the gaskets used by the end-user.

Nominal size

[inch]

Flange class

[lb]

Bolts

Max. torque

[ftlb]

6

150

8 Ч 3/4"

1

8

150

8 Ч 3/4"

1

10

150

12 Ч 7/8"

1

12

150

12 x 7/8"

1

1 Max. torque depends on the gaskets used by the end-user.