Warning, Maintenance – RIKON Power Tools 62-100 User Manual
Page 9
9
Maintenance
Changing the Filters
NOTE: Care should be taken when handling
soiled or contaminated filters. As certain fine
dusts can be harmful. Always wear a suitable
mask for additional protection.
Fig.06
Fig.07
There are two filters that need to be
changed.
The outer filter can be removed by
disengaging the two fliter clips
(A, Fig.06). Pull the filter out, or use a
screwdriver to pry out the filter.
The inner filter (Fig.07) can now be pulled
out of the unit. The inner filter can be
blown out with air, or washed out.
The filters should be replaced depending
on the amount of usage. Clogged filters
will reduce the amount of air circulation.
There is an arrow indicating the air flow
direction on the outer filter. Make sure the
filter is inserted facing the proper
direction.
!
!
WARNING
To reduce the risk of injury disconnect the
air cleaner from the power source (unplug)
before servicing or changing filters. Failure
to comply may cause serious injury!
A