Nature Power 3000W Pure Sine Inverter Charger (38330) User Manual
Page 11
Page 11
Green
LED
ON
(flashing)
Pass-Through Mode (AC mode). Battery Charging is in progress.
Remote LCD Display shows:
- Battery DC Voltage and charging current
- AC Input Voltage and Current
e.g.
AC: 120V 20A DC: 12.0V 50A
Press ‘+’ or ‘-‘ key to check charging stage.
e.g
. Charge Stage ABS
Press ‘+’ or ‘-‘ key to check AC Input Power.
e.g
. System Power 2.4 KW
Fault
Red
LED ON
(solid)
Unit has shutdown. Display shows error code and error message.
- Low battery shutdown
e.g.
FAULT: E01 Low Battery
Push Button Functions on Unit
A beeping sound will occur every time that any button on the unit is triggered.
Button
Function
Power Turns unit On/Off. Press and hold for 1 second to turn unit On/Off
Reset Reset the unit: Press once to reset the unit. This may be required when an error
is detected on the unit
Push Button Functions on Remote Display
A beeping sound will occur every time any button on the unit is triggered.
Button
Function
O
Turns LCD display On/Off. Press and hold for 2 seconds to turn display On/Off.
Display shows unit model number and revision.
e.g.
Nature 38330
Power
REV 1.1
Enter
Save the selected setting or go to the next stage
+
Scroll up on the menu
-
Scroll down on the menu
EXIT
Exiting or entering the feature setting mode
Understanding the Charger Functions
Three-Stage Charging:
The Three-Stage Charging algorithm has a Bulk, then Absorption and then Float sequence.
During the Bulk stage, the battery accepts the maximum constant current from the charger. In
the Absorption stage, the battery voltage is held to constant voltage and the charging will
slowly reduce. In Float stage, the charger continuously produces voltage at a lower level to
fully top up the battery and maintain the battery in a fully charged state.
The charger will automatically restart the charging cycle in Bulk stage if the battery is
discharged to 12.5V. Also, after seven days, the charger will automatically restart the
recharging cycle to refresh the battery.
Battery Type:
Three types of battery setting (GEL, AGM and Flooded) are available. See reference battery
charging voltage as shown:
Battery Type
Absorption
Float
Equalization
GEL
14.4 V
13.8 V
N.A.
AGM
14.3 V
13.45 V
N.A.
Flooded
14.4 V
13.5 V
16.0 V
Equalize the Flooded Battery:
For Flooded battery type, equalization mode is available. Use the following procedure to
equalize the flooded battery. See also section 5 on setting EQ mode for flooded battery.
DANGER: Explosion Hazard. The flooded battery generates explosive gases
during equalization. Follow all the battery safety precautions listed in the manual.
CAUTION:
Risk of Battery and Equipment damage. Only a Flooded lead-acid battery can