Johnson Level & Tool Mfg. 40-6770 User Manual
Page 5
©2010 Johnson Level & Tool
5
2. Fine detection
1. power symbol
2. fine detection symbol
• Press coarse/fine detection button. The
detector is ready for fine detection.
• Move the detector slightly up and
down like the coarse detection
procedure.
• When the detector displays as shown
in the figure, it is level with the laser
beam.
• Tighten the adjusting bolt and mark the position on the grade rod
next to the rabbet. This mark will be the horizontal reference in the
fine detection.
(e) Sound function
• If the detector is working in a situation where it is difficult to use
the display function, the sound function can be used instead.
• Press the sound function button. The sound symbol is displayed
and the detector is ready for sound function. The detector then
conducts detection through sound (horn) signals.
• When the sound signal is a short sound, move the detector slightly
upwards.
• When the instrument makes a rapid sound, move it slightly downwards.
• When the instrument makes a continuous sound, it is level with
the laser beam.
• If there is no sound heard, the detector is not receiving the laser
signal.
3708H_Manuals 7/20/10 11:27 AM Page 5