4.1. Technical Specifications

Inputs

2 balanced ¼” TRS, 2 unbalanced RCA, 1 stereo 1/8”

Performance

Frequency Response

70 Hz to 20 kHz

Crossover Frequency

2.8 kHz

Amplifier Power

25W per speaker

Peak SPL at 1m

100 dB

Input Impedance

10 kΩ

User Controls

Volume Range

A-Type Taper

MF Control

Variable (-6 to +6 dB)

HF Control

Variable (-6 to +6 dB)

Low Cut

Flat, 80 Hz, 100 Hz

Acoustic Space

Flat, -2 dB, -4 dB

Protection

RF interference, output-current limiting, over-temperature,

turn on/off transient, subsonic filter, external mains fuse

Power

100-120V ~50/60 Hz or 220-240V ~50/60 Hz

Physical

Cabinet

Vinyl laminated MDF

Dimensions (WxHxD)

6.42” x 9.45” x 7.09” (163 mm x 241 mm x 180 mm)

Weight (per pair)

13 lbs (5.9 kg)

4.2. Troubleshooting

No Power. First ensure that your active Eris E4.5 is plugged

in. If it’s connected to a power conditioner, verify that the

power conditioner is turned on and functioning.
No audio. If your Eris E4.5 appears to power on but you hear no

sound when playing audio from your audio source (the lights are on

but nobody’s home), first make sure that the cable connecting your

audio source to the monitor is working correctly. Also, verify that the

volume control is set to provide enough amplitude for the signal.
If only the passive E4.5 is not passing audio, check

your speaker-wire connections and verify that the bare

wire is fully inserted into each connection.