beautypg.com

Warning, Draining recovered oil – MAHLE RTI Matco AC880 User Manual

Page 8

background image

Page 7

WARNING

Failure to perform the Drain Oil procedure after every recycle
procedure will cause the AC880 to eventually fail.

Repair of the AC880 to correct this problem is not covered by
warranty.

DRAINING RECOVERED OIL

Oil is separated from the recovered refrigerant and MUST be removed following
EACH Recover/Recycle procedure to determine the amount (if any) necessary to
add into the A/C System as follows:

Note:

The AC880 must be connected to power source. Draining
Recovered Oil may be done while the AC880 Vacuum Pump is ON.

1.

Setup the AC880 as shown on Page 4 and press and hold the Oil Drain Re-
pressurization Switch for 5 seconds and then release it.

2.

Slowly open the valve on Oil Drain Bottle to drain any oil which may have
been removed from the A/C System.

Unless the A/C System had previously been overfilled, the AC880 will
typically not remove enough oil to make replenishment necessary.

3.

Close the valve on the Oil Drain Bottle.

4.

Press and hold the Oil Drain Re-pressurization Switch for 5 seconds. This
permits any residual Non-Condensable Gas to be re-circulated for