Specification mydata smd tower 2000, Capability, Capacity – MYDATA SMD Tower 2000 User Manual
Page 2: Cassettes, Software, Accessory

SpecificATion MYDATA SMD ToWeR 2000
Reel sizes
8 to 24 mm (4” / 100 mm reels)
8 to 24 mm (7” / 180 mm reels)
8 to 44 mm (13” / 330 mm reels)
freely configurable and expandable
Access time
15 seconds
RAnDoM AcceSS SToRAge SYSTeM foR SMD ReelS
cApAbiliTY
STAnDARD configuRATion
Reel WiDTh
cASSeTTeS / SMD ToWeR
ReelS / cASSeTTe
no of ReelS
ToTAl
8 mm / 4” - 7“
21
14
294
562
8 mm / 13“
5
14
70
12 mm / 4” - 7“
3
12
36
12 mm / 13“
3
12
36
16 mm / 4” - 7“
4
10
40
16 mm / 13“
2
10
20
24 mm / 4” - 7“
2
8
16
24 mm / 13“
3
8
24
32 mm / 13“
3
7
21
44 mm / 13“
1
5
5
56 mm / 13“
0
4
0
MAxiMuM Reel cApAciTY
Reel WiDTh
cASSeTTeS / SMD ToWeR
ReelS / cASSeTTe
no of ReelS
ToTAl
8 mm / 4” - 7“
30
14
420
658
8 mm / 13“
17
14
238
MAxiMuM TRAY cApAciTY
cASSeTTe WiDTh
cASSeTTeS / SMD ToWeR
TRAY boxeS / cASSeTTe
no of TRAY boxeS
ToTAl
32 mm / 13“
17
7
119
357
cASSeTTe cApAciTY
cASSeTTe TYpe
nuMbeR
4” - 7“
30
13“
17
cApAciTY
cASSeTTeS AvAilAble
Reel WiDTh
Reel DiAMeTeRS
4” - 7“
13“
8 mm
•
•
12 mm
•
•
16 mm
•
•
24 mm
•
•
32 mm
1)
•
44 mm
•
56 mm
•
1)
32 mm cassettes can alternatively house tray boxes.
1 Tray box = 3 Trays (JeDec)
cASSeTTeS
SofTWARe funcTion
STAnDARD MoDe
MYlAbel MoDe
component management
•
*
Stock monitoring
•
*
external communication protocol
•
•
user Access System
•
•
Traceability
•
•
Job preparation
•
*
barcoding
•
*
Data import / export function
•
*
inventory function
•
*
component allocation
•
MYlabel integration
•
* handled by MYlabel / MYplan software.
SofTWARe
2)
nitrogen possible on request.
DRY AiR uniT fReY fnD 3.0 f-Dp
flow rate, max
(in) 24 m
3
/h, (out) 20 m
3
/h
flow rate, typ.
3 m
3
/h
Air supply
class 4 (iSo 8573-1) or better
operating pressure
5 - 10 bar
power supply
115 / 230 v, 50/60 hz, 18W
Dimension (W x D x h)
330 mm x 270 mm x 840 mm (13,0“ x 10,6“ x 33,1“)
AcceSSoRY