Components, The local unit (ce-220l), Front view – ATEN CE-220L User Manual
Page 6

- 4 -
Components
The Local Unit (CE-220L)
Front View:
#
Description
Function
1
Operating
Mode Selection
Switch
Pressing this button toggles between the operating
mode choices:
Local: only the local console can control the system(s)
Auto: both consoles can control the system(s).
2
LEDs
The Local Unit has two LEDs to indicate the operating
status of the Local and Remote units (see CE-220L
(Local Unit), p. 9).
3
Mouse Port
The local PS/2 mouse plugs into this connector.
4
Keyboard Port
The local PS/2 keyboard plugs into this connector.
5
Monitor Port
The local monitor plugs into this connector.
6
Remote I/O
The Cat 5 twisted pair cable that connects to the Remote
Unit plugs into this connector.
7
Range Switch
Slide the switch to the Long position if the Remote Unit
is located a long distance away (greater than 30m); slide
the switch to the short position if the Remote Unit is a
short distance away.
8
Power Jack
The cable from the AC Power Adapter plugs into this
jack.
1
2
3
4
5
6
7
8
C
O
N
S
O
L
E
R
E
M
O
T
E
I
/ O
L
O
N
G
S
H
O
R
T
R
A
N
G
E
AC 9V
CE220.fm Page 4 Wednesday, November 22, 2006 10:55 AM