Wire toxic gas sensor module model tox45-xx, Toxalert international, inc, Specifications – Toxalert Tox-45-xx Series User Manual
Page 2: Output, Electrical data

TOXALERT INTERNATIONAL, INC.
P.O. BOX 159, MOUND, MINNESOTA 55364 * (952) 472‐4541 * FAX (952) 472‐4960
Visit our website at www.toxalert.com
Construction:
Dimensions: 7.0 x 3.6 x 4.0 in. (H x W x D)
(17.8
x
9.1
x
11.2
cm.)
TOX45-25/26
8.4 x 4.4 x 3.9 in (H x W x D)
(21.3 x 11.2 x 9.9 cm.)
Weight:
2.2 lb. (1.0 Kg) Al
4.6 lb. (2.1 Kg) SS
TOX45-25/26
3.0 lb. (1.3 Kg) Al
5.0 lb. (2.3 Kg) SS
Enclosure:
Nema 4X, Nema 7
Aluminum
or
Stainless
Steel
Limited warranty: 1 Year
2-Wire Toxic Gas Sensor Module Model TOX45-XX
Specifications
:
Specifications subject to change without notice
Ordering Information:
Model - Gas - Enclosure
Accessories
TOX45 Series
-03 = O
2
- A1 (Aluminum)
4511-00 Rainshield
-04 = CO
- S1 (Stainless Steel)
4511-02 Rainshield with calibration port
-05 = H
2
S
4558-01
Calibration
Adaptor,
Standard
-06 = Cl
2
4558-51
Calibration/configuration
magnetic
tool
-08 = CIO
2
4560-00
Calibration
gas
delivery
fitting
-10 = SO
2
-12 = NO
2
-25 = NH
3
-26 = HF
Example: TOX45-04-A1=CO Sensor with aluminum enclosure
Performance
Max. Gas Range (1 ) Resolution
Response Time (2)
Sensor Life
TOX45 -03 O
2
0 - 25 % Vol
0 .2 % Vol.
< 1 0 Seconds
20 Months
TOX45 -04 CO
0 – 1000 PPM
0 . 5 PPM
<25 Seconds 2
Years
TOX45 -05 H
2
S
0 - 100 PPM
0 . 1 PPM
<30 Seconds 2
Years
TOX45-06 Cl
2
0 - 10 PPM
0 . 1 PPM
<60 Seconds
2 Years
TOX45-08 ClO
2
0 - 3 PPM
0 . 1 PPM
<60 Seconds
2 Years
TOX45 -1 0 SO
2
0 - 100 PPM
0 . 5 PPM
<20 Seconds 2
Years
TOX45-1 2 N O
2
0 - 20 PPM
0 .2 PPM
<35 Seconds
2 Years
TOX45 - 25 NH
3
0 - 100 PPM
1 .0 PPM
<30 Seconds (3)
TOX45-26 HF
0 - 10 PPM
1 .0 PPM
<90 Seconds
(3)
(1) Other ranges available
(2) To 90% range
(3) Ammonia and HF sensor
Requires electrolyte
recharge up to one (1)
Year
“intervals”.
Output:
Display:
LCD, 2‐line, 16‐characters
Signal Output:
2‐wire sensor powered analog 4‐20mA
(Trouble: 3.6 mA)
Loop Resistance:
800 ohm
Electrical Data:
Power Consumption: 0.2 watts
Connection Type:
2‐wire, loop‐powered
Input Voltage:
24 VDC nominal: 14‐30VDC
RFI/EMI Protection:
EN50081‐2, EN50082‐2
Operating Range:
Ambient Temp Range:
Standard:
‐4° to 122°F (‐20° to 50°C)
TOX45‐25/26
14° to 113°F (‐10° to 45°C)
Extended Temp:
Sensor and 4‐20mA will continue to operate
to ‐40°F (‐40°C) but the LCD display will decay
over time if exposed to temperatures below
‐4°F (‐20°C) for significant time (not for TOX45‐25)
Storage Temp:
‐4°F to 122°F (‐20° to 50°C)
Relative Humidity:
Standard:
15‐90%
TOX45‐25 NH
3
20‐90%
TOX45-xx
4.12