MODEL TOX-HCl/ANA

SPECIFICATIONS:

••••

Type: Electrochemical cell-diffusion barrier type

••••

Operating Temperature : 4

°

to 122

°

F

••••

Range: 0 to 20 ppm hydrogen chloride in air

-20

°

to 50

°

C

••••

Response Time: 100 seconds to 90% indication

••••

Relative Humidity: 15 to 90% RH non-

••••

Typical Life: Two years in normal service

condensing


••••

Electrical Data:

Input

Voltage:

14 – 30 vdc

Output Signal: Linear 4 to 20 mA

Input Power: 1.4 Watt

Signal Output-Trouble: 0 mA

Input Current: 40 mA @ 28 vdc

Wiring: 3 wire non-isolated

Loop Resistance: 800 Ohms

••••

Unit Construction:

Mounting:

Conduit ¾” NPT or flexible cable

Physical: H: 7.6”, D: 4.6”, W: 4.2”

Housing:

Explosion proof (Nema 7)

Weight: 2.7 pounds

(Div 1, Class 1, Groups C, D)

Gas Sensor Modules available from Toxalert
include:


Ammonia (NH3)

Combustible Gas
Carbon Monoxide (CO)
Carbon Dioxide (CO2)

Chlorine (Cl2)

Oxygen (O2)

Hydrogen (H2)

Hydrogen Chloride (HCl)
Hydrogen Cyanide (HCN)
Hydrogen Sulfide (H2S)

Nitric Oxide (NO)
Nitrogen Dioxide (NO2)

Ethylene Oxide (ETO)
Refrigeration
And more….