background image

x 10" (8.3 x 25.4 cm) vent system

x 10" (8.3 x 25.4 cm) vent system

Maximum length

= 35 ft

(10.7 m)

1 - 90° elbow

= 5 ft

(1.5 m)

8 ft (2.4 m) straight

= 8 ft

(2.4 m)

1 - wall cap

= 0 ft

(0 m)

Length of

x

10" (8.3 x 25.4 cm) system

= 13 ft

(3.9 m)

x 10"

(8.3 x 25.4 cm)
90° elbow =
5 ft (1.5 m)

x 10"

(8.3 x 25.4 cm)
flat elbow =
12 ft (3.7 m)

x 10"

(8.3 x 25.4 cm)
wall cap =

0 ft (0 m)

2 ft
(0.6 m)

6 ft ( 1.8 m)

wall cap

x 10"

(8.3 x 25.4 cm)
elbow

Maximum length

= 35 ft

(10.7 m)

1 - 90° elbows

= 5 ft

(1.5 m)

8 ft (2.4 m) straight

= 8 ft

(2.4 m)

1 - wall cap

= 0 ft

(0 m)

Length of 7"
(17.8 cm) system

= 13 ft

(3.9 m)

6" (15.2 cm) or larger vent system

x 10"

(8.3 x 25.4 cm) to
6" (15.2 cm) or

90° elbow =
5 ft (1.5 m)

45° elbow =
2.5 ft (0.8 m)

x 10" (8.3

x

25.4

cm) to 6"

(15.2 cm) or

6" (15.2 cm)

wall

cap

=

0

ft (0

m)

6" (15.2 cm) or larger round vent system

or larger

larger = 4.5 ft
(1.4 m)

= 5 ft (1.5 m)

larger 90° elbow

Wall cap

90˚ elbow

2 ft

(0.6 m)

6 ft (1.8 m)

Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.