31 2 troubleshooting & care, English – Pfister F-029-4SLS User Manual
Page 3

3
1
2
Troubleshooting & Care
Cleaning Instructions:
For all handles and decorative finishes, use only a soft damp cloth to clean and
shine. Use of polish, detergents, abrasive cleaners, organic solvents or acid may
cause damage. Use of anything other than a soft damp cloth will nullify the
warranty.
Diverter Removal
Cartridge Removal
Aerator Cleaning
Push up on Hose (A)
holding Collet (B) in
place, then, pull Hose (A)
downward until it is free
from Diverter (C).
Remove Clip (D) from
Diverter (C). Remove
Diverter (C) from
Connector (E).
Symptom
Possible Causes
Solution
See Image
Low water flow from spout
Clogged Aerator
Clean debris from aerator
2
Clogged Diverter
Replace diverter. Contact Pfister
™ for replacement part.
1
Leak from handle
Loose Retainer Nut
Remove Handle and tighten brass retainer nut.
3
Dripping when turned off
Clogged Cartridge
Replace Cartridge. Contact Pfister
™ for replacement part.
3
Erratic flow from spout
Clogged Aerator
Clean debris from aerator.
1
Turn off water supplies and relieve pressure before working on your faucet!
¡
1-800-PFAUCET (732-8238)
pfisterfaucets.com
For Warranty & Care Information or
Ordering Replacement Parts:
English
A
A
B
C
D
E
D
C
E
Aerator
Aerator Tool
Retainer Nut
Cartridge
Hex Wrench