Models VDA05, VDA07, VDA10 Page 1

The Versa-Matic Surge Dampener reduces flow and pressure pulsation which is

characteristic of reciprocating pumps.

PRINCIPLE OF OPERATION

The surge dampener uses a flexible virgin PTFE diaphragm to separate a liquid

chamber from a compressed air chamber. After the dampener is manually

charged with air, the diaphragm strokes at the same rate as the pump strokes.

This movement effectively "dampens" flow and pressure fluctuations.

TEMPERATURE LIMITATIONS

Operating temperature limitations are as follows.

Material

Minimum Temp.

Maximum Temp.

PVDF

0°F/ -18°C

212°F / 100°C

Nylon

32°F/ 0°C

180°F / 82°C

Polypropylene

32°F/ 0°C

180°F / 82°C

Virgin PTFE

-35°F/ -31°C

212°F / 100°C

Nitrile

-10°F/ -23°C

190°F / 88°C

INSTALLATION & START-UP

Locate the unit in the discharge piping near the pump. The dampener will operate

in any position. However, when used with liquids that tend to settle out, the unit

should be installed at the top side of piping to provide easy discharge of foreign

solids by gravity.

Adjust the inlet air pressure to the dampener until the pump runs as smoothly

as possible. Watch the liquid discharging, or use a gauge, to detect pressure

fluctuations. Then adjust pressure to the unit as needed.

NOTE: Self-relieving regulator 020-039-000 will make these adjustments easier.

SERVICE

When service is required on the dampener, remove the 8 capscrews. The wetted

chamber can be removed from the unit and exposes the diaphragm. Remove the

diaphragm. When reassembling the wetted chamber onto the air chamber, use

a torque wrench set at 70 in/lbs. (7.9 Newton meters)

WARRANTY

This unit is guaranteed for a period of five years against defective material and

workmanship.

SERVICE AND OPERATING MANUAL

Model VDA05 ½" Surge Dampener

Model VDA07 ¾" Surge Dampener

Model VDA10 1" Surge Dampener

Before surge dampener

operation, inspect all

gasketed fasteners for

looseness caused by

gasket creep. Re-torque

loose fasteners to prevent leakage. Follow

recommended torques stated in this manual.

CAUTION

IMPORTANT

Read these safety warnings

and instructions in this

manual completely, before

installation and start-up

of the surge dampener. It

is the responsibility of the purchaser to retain

this manual for reference. Failure to comply with

the recommendations stated in this manual will

damage the surge dampener, and void factory

warranty.

M a x i m u m

operating pressure

is 100 psi (7 bar).

Limitation are

based upon mechanical stress only and may

be significantly altered by pumping certain

chemicals. Consult engineering guides for

chemical compatibilities and temperature limits.

CAUTION