Npt air ports, Warning – Versa-Matic Liquid Level Control User Manual
Page 3
www
.
versamatic
.
com
Liquid Level Control •
3
vmllcsm-rev0513
Float Actuated Air Valve
Grounding the Liquid Level Control
16
5
17
18
2
4
14 15
6
3
17
9
2
QT
AIR INLET
12
19
13
8
13
7
16
17
1
7
17
3
18
17
9
21
1
2
19
3
TO PUMP
17
6
20
12
4 11
17
5
R
L
10
17
18
WASHER, FLAT, 1/4
WASHER, LOCK, 1/4
VALVE, FLOAT
VALVE, DIAPHRAGM
21
20
19
18
901-002-330
900-001-330
893-092-000
893-024-000
1
2
1
1
FITTING, TUBE, 90˚ ELBOW
TUBE, POLYETHYLENE
SPRING, COMPRESSION
ROD, DETENT
ROD, TABULATED
NUT, ELASITIC STOP
NUT, HEX
NIPPLE, PIPE
FLOAT
COUPLING, RIGID
COLLAR, SET SCREW
CLAMP, ASSEMBLY
CLAMP, U-BOLT
CAPSCREW, HEX HD
BRACKET, VALVE
BRACKET, FLOAT ROD
BRACKET, FLOAT ROD
255-005-114
8
13
15
17
16
14
12
11
10
9
685-015-114
866-063-000
860-049-550
780-015-115
685-016-330
547-003-330
545-003-330
538-006-335
345-001-115
6
7
5
4
3
2
ITEM
1
220-003-115
200-011-330
200-010-330
170-043-330
PART NO
115-151-330
115-150-330
115-024-330
1
2
1
4
2
1
1
2
1
1
DESCRIPTION
1
2
1
2
1
1
1
18A
18B
TUBE, STOP
860-015-080
1
A
8
1
SPRING, COMPRESSION
780-014-080
1
B
8
1
SERVICE KIT
RK118:A
18D
18C
1
18E
L
R
[189]
7
7 16
9
1
16
[229]
7
7¼
[185]
9
13
16
[249]
12¾
[324]
3
3 16
[81]
1¾
[44]
MAX. LENGTH
(SEE BELOW)
5¾
[147]
ADJUSTABLE
COLLARS
ROD COUPLER, WHEN RQD.
ROD
FLOAT
1½ STD. PIPE
[ ] METRIC DIMENSIONS (MILLIMETERS)
TO PUMP (½ NPT)
AIR INLET (½ NPT)
½ NPT AIR PORTS
FEET
METERS
FEET
METERS
3.0
.914
3.8
1.16
6.0
1.83
6.8
2.07
9.0
2.74
9.8
2.99
ROD LENGTH
ASS'Y LENGTH
NOTE: RODS ARE SUPPLIED IN 3 FT.
[.91M] LENGTHS. THE FLOAT SUPPLIED
IS 6 IN. [152MM] IN DIAMETER
MINIMUM FLOAT TRAVEL=1½"
*
* MAX. ROD LENGTH
10 PSI (0.7 BAR ) MIN. AIR PRESSURE
125 PSI (8.6 BAR ) MAX. AIR PRESSURE
2
2
18C
18D
18E
REPAIR PARTS LIST
DIAPHRAGM VALVE
Optional 8 foot long (244 centimeters) 920.025.000 Grounding Cable is available
for easy ground connection. Install one eyelet on the grounding cable to hardware
on the product and the other eyelet to a natural earth ground.
To reduce the risk of static electrical sparking, this Liquid Level Control unit must
be grounded. Check the local code for detailed grounding instruction and the type
of equipment required.
WARNING
Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
Liquid Level Control, piping, valves,
containers or other miscellaneous
equipment must be grounded.
16
5
17
18
2
4
14 15
6
3
17
9
2
QT
AIR INLET
12
19
13
8
13
7
16
17
1
7
17
3
18
17
9
21
1
2
19
3
TO PUMP
17
6
20
12
4 11
17
5
R
L
10
17
18
WASHER, FLAT, 1/4
WASHER, LOCK, 1/4
VALVE, FLOAT
VALVE, DIAPHRAGM
21
20
19
18
901-002-330
900-001-330
893-092-000
893-024-000
1
2
1
1
FITTING, TUBE, 90˚ ELBOW
TUBE, POLYETHYLENE
SPRING, COMPRESSION
ROD, DETENT
ROD, TABULATED
NUT, ELASITIC STOP
NUT, HEX
NIPPLE, PIPE
FLOAT
COUPLING, RIGID
COLLAR, SET SCREW
CLAMP, ASSEMBLY
CLAMP, U-BOLT
CAPSCREW, HEX HD
BRACKET, VALVE
BRACKET, FLOAT ROD
BRACKET, FLOAT ROD
255-005-114
8
13
15
17
16
14
12
11
10
9
685-015-114
866-063-000
860-049-550
780-015-115
685-016-330
547-003-330
545-003-330
538-006-335
345-001-115
6
7
5
4
3
2
ITEM
1
220-003-115
200-011-330
200-010-330
170-043-330
PART NO
115-151-330
115-150-330
115-024-330
1
2
1
4
2
1
1
2
1
1
DESCRIPTION
1
2
1
2
1
1
1
18A
18B
TUBE, STOP
860-015-080
1
A
8
1
SPRING, COMPRESSION
780-014-080
1
B
8
1
SERVICE KIT
RK118:A
18D
18C
1
18E
L
R
[189]
7
7 16
9
1
16
[229]
7
7¼
[185]
9
13
16
[249]
12¾
[324]
3
3 16
[81]
1¾
[44]
MAX. LENGTH
(SEE BELOW)
5¾
[147]
ADJUSTABLE
COLLARS
ROD COUPLER, WHEN RQD.
ROD
FLOAT
1½ STD. PIPE
[ ] METRIC DIMENSIONS (MILLIMETERS)
TO PUMP (½ NPT)
AIR INLET (½ NPT)
½ NPT AIR PORTS
FEET
METERS
FEET
METERS
3.0
.914
3.8
1.16
6.0
1.83
6.8
2.07
9.0
2.74
9.8
2.99
ROD LENGTH
ASS'Y LENGTH
NOTE: RODS ARE SUPPLIED IN 3 FT.
[.91M] LENGTHS. THE FLOAT SUPPLIED
IS 6 IN. [152MM] IN DIAMETER
MINIMUM FLOAT TRAVEL=1½"
*
* MAX. ROD LENGTH
10 PSI (0.7 BAR ) MIN. AIR PRESSURE
125 PSI (8.6 BAR ) MAX. AIR PRESSURE
2
2
18C
18D
18E
REPAIR PARTS LIST
DIAPHRAGM VALVE