• Model U2 Aluminum Bolted
Performance
U2 - 2” Bolted Aluminum Pump
Flow Rate
Adjustable to . . . . . . . 0-175 gpm (662 lpm)
Port Size
Suction . . . . . . . . . . . . . . . . . . . . . . . 2" NPT
Discharge. . . . . . . . . . . . . . . . . . . . . 2" NPT
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . 3/4" NPT
Suction Lift (Dry)
Rubber . . . . . . . . . . . . . . . . . . . .20' (6.10 m)
PTFE . . . . . . . . . . . . . . . . . . . . .10' (3.05 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . 7/16" (11.1 mm)
Shipping Weights
Aluminum . . . . . . . . . . . . . . . . 75 lbs (34 kg)
NOTE: Performance based on the following: elastomeric fitted pump, flooded suction,
water at ambient conditions. The use of other materials and varying hydraulic conditions
may result in deviations in excess of 5%.
NOTE:For U2 pumps fitted with PTFE diaphragms, reduce water discharge figures
by 20%.Suction lift is reduced to 10' (3.05m) dry and 20' (6.10m) wet.
CAUTION: Do not exceed 125 psig (8.5 bars) air supply or liquid pressure.
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M3/HR
20
34
40
68
60
102
80
136
100
170
120
204
140
238
160
272
160
140
120
100
80
60
40
20
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Meters Feet
Discharge Head in PSI
0
0
20
40
60
80
100
120
20
40
60
80
100 120 140 160 180 200
100
0
200
300
400
500
600
700
Displacement Per Stroke, 0.47 Gal. (1.78L)
75
70
65
80
60
55
50
45
40
35
30
25
20
15
10
5
0
240
220
260
200
180
160
140
120
100
80
60
40
20
0
1: PUMP