8 front panel explanations, Onepower line interactive ups (en) – Atlantis Land Line Interactive UPS A03-PS651 _MX01 User Manual
Page 25

OnePower Line Interactive UPS (EN)
A03-PS651 Pag. 21
5. When UPS is operating, press POWER button and hold 3
seconds until switch off (Switch off UPS, must turn off the equipment 
which connect to UPS, Then press POWER button). 
 
 
IMPORTANT NOTICE: Plug the UPS into the wall outlet to charge the UPS for 
over 10 hours before using the UPS. 
 
IMPORTANT NOTICE:
Before connect with equipment power supply line,
please count the total equipment watt. The number must lower than UPS 
output watt. If it higher than UPS output watt, please reduce some 
equipment, or UPS will lock under backup power condition (No output 
of UPS, display OVERLOAD or FAULT). 
 
1.8 Front Panel Explanations
On the front panel You can found 3 LED for an easy diagnostic.
LED
Information
Main Switch(4) To Control on/off the UPS when Utility is normal.
To enable “DC-Start” Function when Utility fails. (To enable 
DC Start properly, you are recommended to connect <80% 
output load with the UPS only). P.S. Make sure the 
computer connected to the UPS is switched on before 
enable the "DC-Start" function. You are not recommended 
to add some other computer or peripherals after DC-Start 
function is activated.
NORMAL(1)
Green LED remains standstill when Utility is normal. 
 