beautypg.com

Before opera, Before opera tion tion – Powermate PM0101207 User Manual

Page 6

background image

English

Customer Hotline 1-800-445-1805

6

GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
PROTECTION

Some jobsites and local codes may require GFCI

protection for personnel before operation of your generator. If
your generator is not already equipped with a GFCI
receptacle, GFCI In-line cord sets may be purchased from
your local electrical supply store or home builder appliance
store.

These cord sets are available in various plug and

amperage configurations. (Make sure your generator is
properly Grounded.)

GROUNDING THE GENERATOR

The National Electric Code requires that this product be

properly connected to an appropriate earth ground to help
prevent electric shock. A ground terminal connected to the
frame of the generator has been provided for this purpose.
Connecting a length of heavy gauge (12 AWG min.) copper
wire between the generator Ground Terminal and a copper rod
driven into the ground should provide a suitable ground
connection. However, consult with a local electrician to insure
that local codes are being adhered to.

LUBRICATION

DO NOT attempt to start this engine without filling the

crank case with the proper amount and type of oil. Your
generator has been shipped from the factory without oil in the
crankcase. Operating the unit without oil can damage the
engine.

Fill the engine with oil according to the operator manual.

For units with a dipstick, fill oil to the proper level. Units
without a dipstick should be filled to the top of the opening of
the oil fill.

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If the oil level

becomes lower than required, the sensor will activate a
warning device or stop the engine.

If generator shuts off and the oil level is within

specifications, check to see if generator is sitting at an angle
that forces oil to shift. Place on an even surface to correct this.
If engine fails to start, the oil level may not be sufficient to
deactivate low oil level switch. Make sure the sump is
completely full of oil.

FUEL

Fill the tank with clean, fresh unleaded automotive

gasoline. Regular grade gasoline may be used provided a high
octane rating is obtained (at least 85 pump octane). We
recommend always using a fuel stabilizer. A fuel stabilizer
will minimize the formulation of fuel gum deposits during
storage. The fuel stabilizer can be added to the gasoline in the
fuel tank, or into the gasoline in a storage container.

GROUND TERMINAL LOCATION:

BEFORE OPERA

BEFORE OPERA

TION

TION

Do not use a pipe carrying combustible material as
the ground source.

Do not overfill the tank. Keep maximum fuel level 1/4
inch below the top of the fuel tank. This will allow
expansion in hot weather and prevent overflow.

Ground

Terminal