beautypg.com

Control elements, Pic. 1, Cle 4.0 – Nilfisk-ALTO CLE4.0 User Manual

Page 7

background image

6

3. CONTROL ELEMENTS

Your CLE 4.0 presents with four channels. Each channel is equipped with the same control elements: 3 push-button
switches, 4 rotary controls and 17 LEDs. You can operate in stereo mode via pressing the Couple switch. The details
please refer to following content.

1. Threshold Control for Compressor Section

With this control you will adjust the threshold level in the Compressor. The range is varied from -40dBu to +20dBu. When
a signal exceed the set threshold by 10dB maximum the SKC will be applied, while above such level signal will be processed
with hard knee compression.

8

R

LTO

LIMITER

dBu

BYPASS

dBu

N:1

dBu

N:1

I/O METER

THRESHOLD

RATIO

COMPRESSOR

RATIO

OUTPUT GAIN

dBu

N:1

THRESHOLD

RATIO

COMPRESSOR

OUTPUT GAIN

COMPRESSOR

LIMITER

THRESHOLD

THRESHOLD

dBu

LIMITER

SMART

I/O METER

BYPASS

SMART

COUPLE

CH1 MASTER

COUPLE

CH3 MASTER

OUTPUT GAIN

THRESHOLD

dBu

1

20

40

10

10

20

2

2.5

20

10

10

0

OFF

0

12

BYPASS

I/O METER

SMART

CH1

CH 2

CH 3

THRESHOLD

dB

dB

dB

30

40

10

10

20

30

1

2

2.5

20

20

10

10

0

dB

OFF

0

12

40

10

10

20

30

1

2

2.5

20

20

10

10

0

OFF

0

12

GAIN REDUCTION(dB)

INPUT / OUTPUT LEVEL(dB)

GAIN REDUCTION(dB)

INPUT / OUTPUT LEVEL(dB)

GAIN REDUCTION(dB)

INPUT / OUTPUT LEVEL(dB)

30

25

20

15

10

6

3

1

12

0

LIM

12

6

18

24

6

18

30

25

20

15

10

6

3

1

12

0

LIM

12

6

18

24

6

18

30

25

20

15

10

6

3

1

12

0

LIM

12

6

18

24

6

18

10

4

18

10

4

10

4

18

LIMITER

dBu

BYPASS

N:1

I/O METER

THRESHOLD

RATIO

OUTPUT GAIN

CLE 4.0

Quad

Compressor/

Limiter

ON

OFF

COMPRESSOR

THRESHOLD

dBu

SMART

CH 4

POWER

dB

40

10

10

20

30

1

2

2.5

20

20

10

10

0

OFF

0

12

GAIN REDUCTION(dB)

INPUT / OUTPUT LEVEL(dB)

30

25

20

15

10

6

3

1

12

0

LIM

12

6

18

24

6

18

18

10

4

18

7

10

1

5

2

6

3

4

9

11

13

12

14

OPERATING LEVEL

RING/PIN 3

SLEEVE/PIN 1

TIP/PIN 2

TIP/PIN 2

RING/PIN 3

SLEEVE/PIN 1

CHANNEL 4

CHANNEL 3

CHANNEL 2

CHANNEL 1

OUTPUT

INPUT

OUTPUT

INPUT

OUTPUT

INPUT

OUTPUT

INPUT

dBu

4

10dBV

dBu

4

10dBV

OPERATING LEVEL

OPERATING LEVEL

14W

AC INPUT
95-120V

/210-240V

60-50Hz

Rated Power Consumption

FUSE:
210-240V: T315mAL 250VAC
95-120V: 630mA 250VAC
REPLACE FUSE WITH
CORRECT TYPE ONLY

2

1

3

2

1

3

2

1

3

2

1

3

TIP/PIN 2

RING/PIN 3

SLEEVE/PIN 1

dBu

4

10dBV

OPERATING LEVEL

TIP/PIN 2

RING/PIN 3

SLEEVE/PIN 1

dBu

4

10dBV

110-120V

220-240V

2. Ratio Control

The ratio in between input and output level signals above the set threshold is determined by this control. When the
SKC is applied such ratio is only expressed for the signals exceeding the set threshold more than 10dB. The range
of control of the ratio varies from 1:1 to

:1.

3. Output Gain Control

You can increase or decrease the output signal by a maximum of 20dB. IN such a way you can recover a level lost
during the compression process.

5. Smart Switch

A hard knee compression is turned into SKC by mean of this switch. If you wish to get a compression that is quite
inaudible use the SKC mode through the Smart switch.

4. Bypass Switch

Push this switch and you will deactivate the corresponding channel. You can also use the bypass switch to make an A/B
comparison in between processed and unprocessed signal.

6. Meter Switch for input / output

When this switch is ON the Meter will read the output level. When the switch is OFF, the Meter will read the input
level.

7. Level Meter for Input / Output

You can adjust the operating level by mean of the Operating Level Switch and choose -10dBV or +4dBu. Consequently
the Meter will be the Input or Output Level with a range from -24dB to +18dB.

8. Meter for Gain Reduction

The gain reduction will be shown by this Meter with a range of 1 to 30dB.

Pic. 1