Power Specifications
Table 1-1
lists the current draw values of the ReadyPanel.
Table 1-1. System Current Draw
Notes: *In-rush measured with CRT monitor, LCD panel, touch controller, touch screen, 256MB RAM,
inverter, power, compact flash with Win XPe, keyboard and mouse.
**The BIT (burn in test) is conducted with the same criteria as In-rush plus two serial loopbacks, two
USB jump drives, and one Ethernet port connection.
What’s in the Box
The Contents List identifies the items in the shipping container for the ReadyPanel QuickStart Kit. The first
of multiple boxes may contain all of the accessories on the Contents List. See
Figure 1-1
.
Figure 1-1. ReadyPanel and Accessories
Setup Steps
Make sure to follow the setup steps in this section in the exact order listed but skip any steps that do not
apply to your needs. References are provided to chapters within this guide or other Ampro manuals for more
information about installation and use of this ReadyPanel.
Parameter
+5VDC
+12VDC
Idle
2.11A (10.53W)
0.81A (9.75W)
In-rush*
Current
(Typical)
Max: 2.64A (13.20W)
Min: 0.64A (3.20W)
Max: 1.36A (16.32W)
Min: 0.16A (1.92W)
BIT** Current
(Typical)
2.73A (13.66W)
0.81A (9.67W)
CD-ROM
ReadyPanel 6.5
DC Power In
Cable Adapter