DUAL 400C OPERATING INSTRUCTIONS

IMPORTANT: The compressors have a maximum working pressure of 150 PSI. Always operate the

compressor at or below the MAXIMUM PRESSURE RATING of the compressor. Operation exceeding

maximum pressure ratings and or duty cycle will result in damage to air compressor.

1. Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR.

This feature will protect the air compressor from overheating and causing permanent damage to your air

compressor. The thermal overload protector will automatically cut off power to your air compressor should

the internal operating temperature of the air compressor rise above safe levels during excessive use.

2. Should your air compressor automatically shut off during use, turn power to the system off. The automatic

thermal overload protector will automatically reset when internal temperature of the air compressor drops

below safe levels. After allowing air compressor to cool off for about 30 minutes, you can safely resume use

of the air compressor by turning on the system.

3. To prevent discharge of your battery and to provide peak performance, it is recommended that you keep

the engine running while the air compressor is in use.

4. ONLY OPERATE THE AIR COMPRESSOR IN WELL-VENTILATED AREAS.

Dual 400C Compressor Maintenance & Repairs:

1. Periodically check all electrical and fitting connections. Clean and tighten as needed.

2. Periodically check all mounting screws. Tighten as needed.

3. Replace air filter element periodically. Replacement frequency depends on operating frequency and

operating environment. For frequent use in dusty environment, you should replace air filter element

more often.

4. Regularly clean dust and dirt from compressor.

5. Your air compressor is equipped with permanently lubricated, maintenance-free motor.

Never lubricate compressor.

6. Repairs should be performed by Manufacturer or Manufacturer’s Authorized Service Agencies only.

CAUTION: Never touch the air compressor or fittings connected to the air compressor with bare hands during

or immediately after use. Leader hose and fittings will become very HOT during and after use.

Dual 400C Compressor Installation Tips:

1. Always use the remote intake filter option when possible. This will extend the service life of your compressor.

2. If noise reduction from vibration is desired, using the remote mount option for the inlet filter can reduce

operation noise by up to 25%.

3. Always mount the compressor at a point higher than the inlet port of the tank.

This will keep moisture from being able to seep back to the compressor.

4. When mounting the compressor, use a paint pen on the rubber isolators and cover the side to go against the

chassis or mounting location. Then, simply stamp the compressor against the chassis to make an imprint of

exactly where to drill the mounting holes for the compressor.

PRESSURE SWITCH INSTALLATION

Your VIAIR Onboard Air System comes complete with a heavy duty sealed pressure switch that will turn on the

compressor at 110 PSI, and off at 145 PSI. The pressure switch has a 1/4” NPT inlet and pre-applied

thread sealant.

Pressure Switch with Relay Installation Tips:

1. Both terminals of the pressure switch are positive (+) leads. (The use of a relay is always recommended).

2. Never install your pressure switch in direct line from the inlet port coming from the compressor.

Tank pressure could be misread by the pressure switch. Instead, mount the pressure switch on the

tank where it receives air pressure reading from deflected air in the tank.

2. Never use a pressure switch that is rated beyond your compressor’s rated Maximum Working Pressure

(150 PSI).

3. Replace the Pressure Switch P/N 90227 if the pressure switch becomes faulty or

fails in the future.

4. See Fig. 3 for relay and pressure switch installation tips.